Clinical impact of molecular breast imaging as adjunct diagnostic modality in evaluation of indeterminate breast abnormalities and unresolved diagnostic concerns

Author:

van Loevezijn Ariane A.1,Corion Christinne L.S.2,Zeillemaker Anneke M.3,Wijers Lidy M.H.4,Smithuis Robin H.M.4,Valdés Olmos Renato A.5,van der Hage Jos A.6,de Geus-Oei Lioe-Fee57,Benard Menno8,Pereira Arias-Bouda Lenka M.59

Affiliation:

1. Department of Surgical Oncology, Netherlands Cancer Institute – Antoni van Leeuwenhoek, Amsterdam

2. Department of Surgery, Haaglanden Medisch Centrum, Den Haag

3. Department of Surgery

4. Department of Radiology, Alrijne Hospital, Leiderdorp

5. Department of Radiology, Section of Nuclear Medicine

6. Department of Surgery, Leiden University Medical Centre, Leiden

7. Biomedical Photonic Imaging Group, University of Twente, Enschede

8. Department of Research and Education, Alrijne Hospital

9. Department of Nuclear Medicine, Alrijne hospital, Leiderdorp, The Netherlands

Abstract

Purpose Improvements in molecular breast imaging (MBI) have increased the use of MBI as adjunct diagnostic modality and alternative to MRI. We aimed to assess the value of MBI in patients with equivocal breast lesions on conventional imaging, especially in terms of its ability to rule out malignancy. Methods We selected patients who underwent MBI in addition to conventional diagnostics due to equivocal breast lesions between 2012 and 2015. All patients underwent digital mammography, target ultrasound and MBI. MBI was performed using a single-head Dilon 6800 gamma camera after administration of 600 MBq 99mTc-sestamibi. Imaging was reported according to BI-RADS classification and compared with pathology or follow-up of ≥6 months. Results Of 226 women included, pathology was obtained in 106 (47%) and (pre)malignant lesions were found in 25 (11%). Median follow-up was 5.4 years (IQR 3.9–7.1). Sensitivity was higher for MBI compared to conventional diagnostics (84% vs. 32%; P = 0.002), identifying malignancy in 21 and 6 patients, respectively, but specificity did not differ (86% vs. 81%; P = 0.161). Positive and negative predictive value were 43% and 98% for MBI and 17% and 91% for conventional diagnostics. MBI was discordant with conventional diagnostics in 68 (30%) patients and correctly changed diagnosis in 46 (20%) patients, identifying 15 malignant lesions. In subgroups with nipple discharge (N = 42) and BI-RADS 3 lesions (N = 113) MBI detected 7 of 8 occult malignancies. Conclusion MBI correctly adjusted treatment in 20% of patients with diagnostic concerns after conventional work-up, and could rule out malignancy with a high negative predictive value of 98%.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3