The Utility of Smartphone-Based Thermal Imaging in the Management and Monitoring of Microvascular Flap Procedures

Author:

Hudson Todd,Hogue Elizabeth1,Mullner Donna1,Herrera Fernando,Scomacao Isis

Affiliation:

1. College of Medicine

Abstract

Background Smartphone-based thermal imaging (SBTI) has been reported in the literature to be an easy-to-use, contactless, cost-friendly alternative to standard imaging modalities in identifying flap perforators, monitoring flap perfusion, and detecting flap failure. Our systematic review and meta-analysis aimed to evaluate SBTI's accuracy in perforator identification and secondarily evaluate SBTI's utility in flap perfusion monitoring as well as ability to predict flap compromise, failure, and survival. Methods Following Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines, a systematic review was performed using PubMed from inception to 2021. Articles were uploaded into Covidence and, following duplicate deletion, were initially screened for use of SBTI in flap procedures through title and abstract screening followed by full-text review. The following data points, if provided, were extracted from each included study: study design, number of patients, patient demographics, perforator number and location, flap number and location, room temperature, cooling method, imaging distance, time from cloth removal, primary (SBTI's accuracy in perforator identification), and secondary outcomes (prediction of flap compromise/failure/survival and cost analysis). Meta-analysis was performed using RevMan v.5. Results The initial search yielded 153 articles. Eleven applicable studies with a total of 430 flaps from 416 patients were ultimately included. The SBTI device assessed in all included studies was FLIR ONE. Four studies assessed the SBTI's perforated detection ability and were included in meta-analysis. Smartphone-based thermal imaging correctly identified 378 (93.3%; n = 405) perforators, and computed tomography angiography (CTA) correctly identified 402 (99.2%; n = 402), although in one study SBTI found additional perforators not detected on CTA. A random-effects model was used (I 2 = 65%), and no significant difference in perforator detection ability was found between SBTI and CTA (P = 0.27). Conclusions This systematic review and meta-analysis supports SBTI as user- and cost-friendly ($229.99), contactless imaging modality with perforator detection ability comparable to current criterion-standard CTA. Postoperatively, SBTI outperformed Doppler ultrasound in early detection of microvascular changes causing flap compromise, allowing for prompt tissue salvage. With a minimal learning curve, SBTI seems to be a promising method of postoperative flap perfusion monitoring able to be used by all hospital ranks. Smartphone-based thermal imaging could thus increase flap monitoring frequency and lower complication rates, although further study is warranted.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Surgery

Reference20 articles.

1. Comparison of 2-year complication rates among common techniques for postmastectomy breast reconstruction;JAMA Surg,2018

2. A systematic review of the utility of indocyanine angiography in autologous breast reconstruction;Ann Plast Surg,2021

3. Thermographic assessment of perforating arteries. A preoperative screening method for fasciocutaneous and musculocutaneous flaps;Scand J Plast Reconstr Surg,1986

4. Use of recovery-enhanced thermography to localize cutaneous perforators;Ann Plast Surg,1995

5. Accuracy of infrared thermography for perforator mapping: a systematic review and meta-analysis of diagnostic studies;J Plast Reconstr Aesthet Surg,2021

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3