Clinical Feasibility of 3-Dimensional Magnetic Resonance Cholangiopancreatography Using Compressed Sensing

Author:

Yoon Jeong Hee1,Lee Sang Min1,Kang Hyo-Jin1,Weiland Elisabeth1,Raithel Esther1,Son Yohan1,Kiefer Berthold1,Lee Jeong Min1

Affiliation:

1. From the *Department of Radiology, and †College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea; ‡Siemens Healthcare Gmbh, Erlangen, Germany; §Siemens Healthcare Korea; and ∥Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea.

Abstract

Objective The aim of this study was to evaluate the clinical feasibility of fast 3-dimensional (3D) magnetic resonance cholangiopancreatography (MRCP) using compressed sensing (CS) in comparison with conventional navigator-triggered 3D-MRCP. Materials and Methods This retrospective study was approved by our institutional review board, and the requirement of informed consent was waived. A total of 84 patients (male-to-female ratio, 41:43; mean age, 47.3 ± 18.8 years) who underwent conventional 3D navigator-triggered T2-weighted MRCP using sampling perfection with application optimized contrasts (SPACE) and fast 3D MRCP using SPACE with high undersampling combined with CS reconstruction (CS SPACE; CS-MRCP) on a 3 T scanner were included. Among them, 28 patients additionally underwent 3D breath-hold CS-MRCP (BH-CS-MRCP) with 5.7% k-space sampling. Three board-certified radiologists then independently reviewed the examinations for bile duct and pancreatic duct visualization and overall image quality on a 5-point scale, and image sharpness and background suppression on a 4-point scale, with the higher score indicating better image quality. In addition, diagnostic performance for the detection of anatomic variation and diseases of the bile duct, and pancreatic disease were assessed on a per-patient basis in the subgroup of 28 patients who underwent conventional MRCP, CS-MRCP, and BH-CS-MRCP in the same manner. Results Mean acquisition times of conventional MRCP, CS-MRCP, and BH-CS-MRCP were 7 minutes (419.7 seconds), 3 minutes 47 seconds (227.0 seconds), and 16 seconds, respectively (P < 0.0001, in all comparisons). In all patients, CS-MRCP showed better image sharpness (3.54 ± 0.60 vs 3.37 ± 0.75, P = 0.04) and visualization of the common bile duct (4.55 ± 0.60 vs 4.39 ± 0.78, P = 0.034) and pancreatic duct (3.47 ± 1.22 vs 3.26 ± 1.32, P = 0.025), but lower background suppression (3.00 ± 0.54 vs 3.37 ± 0.58, P < 0.001) than conventional MRCP. Overall image quality was not significantly different between the 2 examinations (3.51 ± 0.95 vs 3.47 ± 1.09, P = 0.75). The number of indeterminate MRCP examinations for the anatomic variation and disease of the bile duct significantly decreased on CS-MRCP, from 16.7%–22.6% to 9.5%–11.9% and 8.4%–15.6% to 3.6%–8.4% in all readers (P = 0.003–0.03). In the 28 patients who underwent BH-CS-MRCP, better image quality was demonstrated than with conventional MRCP and CS-MRCP (4.10 ± 0.84 vs 3.44 ± 1.21 vs 3.50 ± 1.11, respectively, P = 0.002, 0.001). Sensitivities for detecting bile duct disease was 88.9% to 100% on both BH-CS-MRCP and conventional MRCP (P > 0.05), and for detecting pancreatic disease was 66.7% to 83.3% on BH-CS-MRCP and 50.0% to 72.2% on conventional MRCP (P = 0.002 in reader 1, 0.06–0.47 in readers 2–3). Conclusions Compressed sensing MRCP using incoherent undersampling combined with CS reconstruction provided comparable image quality to conventional MRCP while reducing the acquisition time to within a single breath-hold (16 seconds).

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.7亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2025 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3