The factors that influence the diagnostic accuracy and sample adequacy of EUS-guided tissue acquisition for the diagnosis of solid pancreatic lesions

Author:

Sun Liqi,Li Yuqiong1,Song Qiuyue1,Peng Lisi1,Xing Ying2,Huang Haojie1,Jin Zhendong1

Affiliation:

1. Department of Gastroenterology, Changhai Hospital, Navy Military Medical University, Shanghai, China

2. Department of Gastroenterology, 72th Group Army Hospital, Huzhou University, Huzhou, Zhejiang Province, China.

Abstract

ABSTRACT Background and Objectives EUS-guided tissue acquisition (EUS-TA) is the preferred method to acquire pancreatic cancer (PC) tissues. The factors associated with false-negative outcomes and inadequate samples should be explored to gain an understanding of EUS-TA. Methods The patients who underwent EUS-TA for suspected solid PC but whose results were false-negative were analyzed. The PC patients who underwent EUS-TA with true-positive results on the first day of every month during the study period were selected as the control group. The factors influencing diagnostic accuracy and sample adequacy were explored. Results From November 2017 to January 2022, 184 patients were included in the false-negative group, and 175 patients were included in the control group. Multivariate logistic regression demonstrated that the recent acute pancreatitis [odds ratio (OR): 0.478, 95% confidence interval (CI): 0.250–0.914, P = 0.026] and high echo component within the tumor (OR: 0.103, 95% CI: 0.027–0.400, P = 0.001) were independently associated with false-negative EUS-TA results. Meanwhile, using fine-needle biopsy (FNB) needles (OR: 2.270, 95% CI: 1.277–4.035, P = 0.005), more needle passes (OR: 1.651,95% CI: 1.239–2.199, P = 0.005), large tumor size (OR: 1.053, 95% CI: 1.029–1.077, P < 0.001), and high CA-19-9 level (OR: 1.001, 95% CI: 1.000–1.001, P = 0.019) were independently associated with true-positive EUS-TA outcomes. Three needle passes are needed to achieve optimal EUS-TA outcomes. Tumor location in the body/tail (OR: 1.38, 95% CI: 1.01–1.72; P = 0.04), needle passes ≥3 (OR: 1.90; 95% CI: 1.22–2.56; P < 0.001), and using the FNB needle (OR: 2.10; 95%: 1.48–2.85; P < 0.001) were independently related to sample adequacy. Conclusion Numerous factors were identified to be associated with the diagnostic accuracy and sample adequacy of EUS-TA.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3