Assessing the Feasibility of Simplifying the Scanning Protocol for Spinal Metastases With Vertebral Compression Fractures Using Only the Dixon T2-Weighted Sequence

Author:

Jiang Jiuming1,Miao Lei1,Zhang Li1,Shi Zhuo1,Zhang Huanhuan1,Wen Xin1,Hu Sijie1,Xu Libin2,Gong Lihua3,Li Meng1

Affiliation:

1. Diagnostic Radiology

2. Orthopedic Surgery

3. Pathology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.

Abstract

Objective Conventional imaging protocols, including sagittal T1-weighted imaging (T1WI) and water-only T2-weighted imaging (T2WI), are time consuming when screening for spinal metastases with vertebral compression fractures (VCFs). In this study, we aimed to assess the accuracy of using only the Dixon T2-weighted sequence in the diagnosis of spinal metastases with VCFs to determine its suitability as a simplified protocol for this task. Methods This retrospective study included 27 patients diagnosed with spinal metastases and VCFs. Qualitative analysis was performed separately by two musculoskeletal radiologists, who independently performed diagnostic evaluations of each vertebra using both conventional and simplified protocols. McNemar's test was then used to compare the differences in diagnostic results, and Cohen's kappa coefficient was used to assess interobserver and interprotocol agreement. Diagnostic performance values for both protocols, including sensitivity, specificity, and area under the curve, were then determined based on the reference standard. Quantitative image analysis was performed randomly for 30 metastases on T1WI and fat-only T2WI to measure the signal intensity, signal-to-noise ratio, and contrast-to-noise ratio. Results The diagnosis of VCFs by both radiologists was in full agreement with the reference standard. The classification of spinal metastases and diagnostic performance values determined by both radiologists were not significantly different between the two protocols (all P > 0.05), and the consistency between observers and protocols was excellent (κ = 0.973–0.991). The contrast-to-noise ratio of fat-only T2WI was significantly higher than that of T1WI (P < 0.001). Conclusions The Dixon T2-weighted sequence alone performed well in diagnosing spinal metastases with VCFs, performing no worse than the conventional protocol (T1WI and water-only T2WI). This suggests that the Dixon T2-weighted sequence alone can serve as a simplified protocol for the diagnosis of spinal metastases with VCFs, thereby avoiding the need for more intricate scanning procedures.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3