Validity and reliability of the assessment of hand flexors stiffness using a new electromechanical oscillatory device in people with stroke

Author:

Selves Clara12,Lejeune Thierry12,Detrembleur Christine2,Haustrate Marie-Adeline3,Stoquart Gaëtant12

Affiliation:

1. Department of Physical Medicine and Rehabilitation, Cliniques universitaires Saint-Luc, Avenue Hippocrate

2. Institut de Recherche Expérimentale et Clinique (IREC), Neuro Musculo Skeletal Lab (NMSK), Université catholique de Louvain, Avenue Mounier, Brussels

3. Department of Physical Medicine and Rehabilitation, Cliniques Saint Pierre, Avenue Reine Fabiola, Ottignies, Belgium

Abstract

Hyper-resistance after a central nervous system injury has been largely referred to as spasticity, which is but one of its neural components. Assessment largely relies on clinical scales (Modified Ashworth scale – MAS and Modified Tardieu scale, MTS) which are unable to distinguish between the non-neural (tissue-related) and the neural (central nervous system-related) components. This study assessed criterion validity and reliability (reproducibility) of muscle stiffness measures, namely, maximum elastic stiffness (ELmax), viscous stiffness (VI), and path length (L-path) in the hand flexor muscles among people with stroke. Measurements were obtained with a wrist-electromechanical oscillatory device (w-EOD). Twenty-four people with arm impairment after stroke were evaluated with the w-EOD and clinical assessment (MAS and MTS), twice on the same day (short-term reliability) and once 10 days later (long-term reliability). For criterion validity, a Spearman coefficient (r) was calculated between stiffness values and the clinical scales. For reliability, intraclass correlation coefficients (ICCs), SEM, and MDC95 were calculated. Moderate correlations were observed between ELmax and MAS (r = 0.49) and MTS (V2, r = 0.43; V3, r = 0.49) of the wrist flexors, and finger flexors (MAS, r = 0.60; MTS V2, r = 0.56; MTS V3, r = 0.55). There was a poor correlation between the clinical scales and VI and L-path. Reliability was excellent for all stiffness measurements at short term (ELmax: 0.95, VI: 0.94, L-path: 0.92) and good at long term (ELmax: 0.87, VI: 0.76, L-path: 0.82). In conclusion, stiffness measurements are valid and reliable to evaluate hyper-resistance in people with stroke.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Rehabilitation,Physical Therapy, Sports Therapy and Rehabilitation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3