The Effects of Unitizing Nail–Plate Constructs in Distal Femur Fractures: A Biomechanical Study

Author:

Mayer Erik1,Lendhey Matin2,Kelley Benjamin1,Shi Brendan1,Upfill-Brown Alexander1,Devana Sai K.1,Brodke Dane1,Shah Akash1,Sekimura Troy1,Gudapati Varun1,Zukotynski Brian1,Park Jeannie1,Witt Amber R.2,Marciante Mara2,Mahoney Jonathan M.2,Bucklen Brandon S.2,Lee Christopher1

Affiliation:

1. Department of Orthopaedic Surgery, University of California Los Angeles, Los Angeles, CA; and

2. Musculoskeletal Education and Research Center, A Division of Globus Medical, Inc., Audubon, PA .

Abstract

OBJECTIVES: To assess the biomechanical differences between linked and unlinked constructs in young and osteoporotic cadavers in addition to osteoporotic sawbones. METHODS: Intraarticular distal femur fractures with comminuted metaphyseal regions were created in three young matched pair cadavers, three osteoporotic matched pair cadavers, and six osteoporotic sawbones. Precontoured distal femur locking plates were placed in addition to a standardized retrograde nail, with unitized constructs having one 4.5 mm locking screw placed distally through the nail. Nonunitized constructs had seven 4.5 mm locking screws placed through the plate around the nail, with one 5 mm distal interlock placed through the nail alone. Cadaveric specimens were subjected to axial fatigue loads between 150 and 1500 N (R Ratio = 10) with 1 Hx frequency for 10,000 cycles. Sawbones were axially loaded at 50% of the ultimate load for fatigue testing to achieve runout, with testing performed with 30 and 300 N (R Ratio = 10) loads with 1 Hz frequency for 10,000 cycles. RESULTS: In young cadavers, there was no difference in the mean cyclic displacement of the unitized constructs (1.51 ± 0.62mm) compared to the non-unitized constructs (1.34 ± 0.47mm) (Figure 4A), (p = 0.722). In osteoporotic cadavers, there was no difference in the mean cyclic displacement of the unitized constructs (2.46 ± 0.47mm) compared to the non-unitized constructs (2.91 ± 1.49mm) (p =0.639). There was statistically no significant difference in cyclic displacement between the unitized and non-unitized groups in osteoporotic sawbones(p = 0.181). CONCLUSIONS: Linked constructs did not demonstrate increased axial stiffness or decreased cyclical displacement in comparison to unlinked constructs in young cadaveric specimens, osteoporotic cadaveric specimens, or osteoporotic sawbones.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3