Do Long-Segment Blocking Screws Increase the Stability of Intramedullary Nail Fixation in Proximal Tibia Fractures, Eliminating the “Bell-Clapper Effect?”

Author:

Stenquist Derek S.1ORCID,McCaskey Meghan1,Diaz Miguel2,Munassi Steven D.2,Ayala Giovanni2,Donohue David1,Mir Hassan R.1

Affiliation:

1. Orthopaedic Trauma Service, Tampa General Hospital/Florida Orthopaedic Institute, Tampa, FL; and

2. Foundation for Orthopaedic Research and Education (FORE), Tampa, FL.

Abstract

OBJECTIVES: To determine change in stiffness and horizontal translation of a geriatric extra-articular proximal tibia fracture model after intramedullary nailing with distal (long)-segment blocking screws versus proximal (short)-segment blocking screws. METHODS: Unstable extra-articular proximal tibia fractures (OTA/AO 41-A3) were created in 12 geriatric cadaveric tibias. Intramedullary nails were locked with a standard construct (4 proximal screws and 2 distal screws). Specimens were then divided into 2 groups (6 matched pairs per group). Group 1 had a blocking screw placed lateral to the nail in the proximal segment (short segment). Group 2 had a blocking screw placed 1 cm distal to the fracture and medial to the nail (long segment). Specimens were then axially loaded and cycled to failure or cycle completion (50,000 cycles). RESULTS: Long-segment blocking screws significantly decreased the amount of horizontal translation at the fracture site compared with short-segment screws (0.77 vs. 2.0 mm, P = 0.039). They also resulted in a greater trend towards greater baseline stiffness, (807.32 ± 216.95 N/mm vs. 583.12 ± 130.1 N/mm, P = 0.072). There was no difference in stiffness after cyclic loading or survival through 50,000 cycles between the long-segment and short-segment groups. CONCLUSION: Long-segment blocking screws added to an intramedullary nail construct resulted in decreased horizontal translation at the fracture site compared with short-segment screws in this model of a geriatric proximal tibia fracture. CLINICAL RELEVANCE: Blocking screws are commonly used to aid in fracture alignment during intramedullary nailing of proximal tibia fractures. Even when not required to attain or maintain alignment, the addition of a blocking screw in either the proximal or the distal (long) segment may help mitigate the “Bell-Clapper Effect” in geriatric patients.

Funder

AO North America

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Orthopedics and Sports Medicine,General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3