Study Design. Retrospective review of prospectively collected data. Objective. To analyze the learning curves of three spine surgeons for robotic minimally invasive transforaminal lumbar interbody fusion (MI-TLIF). Summary of Background Data. Although the learning curve for robotic MI-TLIF has been described, the current evidence is of low quality with most studies being single-surgeon series. Materials and Methods. Patients who underwent single-level MI-TLIF with three spine surgeons (years in practice: surgeon 1: 4, surgeon 2: 16, and surgeon 3: two) using a floor-mounted robot were included. Outcome measures were operative time, fluoroscopy time, intraoperative complications, screw revision, and patient-reported outcome measures. Each surgeon’s cases were divided into successive groups of 10 patients and compared for differences. Linear regression and cumulative sum (CuSum) analyses were performed to analyze the trend and learning curve, respectively. Results. A total of 187 patients were included (surgeon 1: 45, surgeon 2: 122, and surgeon 3: 20). For surgeon 1, CuSum analysis showed a learning curve of 21 cases with the attainment of mastery at case 31. Linear regression plots showed negative slopes for operative and fluoroscopy time. Both learning phase and postlearning phase groups showed significant improvement in patient-reported outcome measures. For surgeon 2, CuSum analysis demonstrated no discernible learning curve. There was no significant difference between successive patient groups in either operative time or fluoroscopy time. For surgeon 3, CuSum analysis demonstrated no discernible learning curve. Even though the difference between successive patient groups was not significant, cases 11 to 20 had an average operative time of 26 minutes less than cases 1–10), suggesting an ongoing learning curve. Conclusions. Surgeons who are well-experienced can be expected to have no or minimal learning curve for robotic MI-TLIF. Early attendings are likely to have a learning curve of around 21 cases with the attainment of mastery at case 31. Learning curve does not seem to impact clinical outcomes after surgery. Level of Evidence. Level 3.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3