Biomechanical Performance of Biodegradable Screw Fixation in Mandibular Distraction Osteogenesis

Author:

Firriolo Joseph Mark1,Xue Yunfeng1,Weyerbacher Jonathan S.1,Saldana Golddy M.1,Garfinkel Alec2,Garcia Tanya C.3,Arzi Boaz3,Wong Granger B.1

Affiliation:

1. Division of Plastic and Reconstructive Surgery, University of California Davis, Sacramento

2. California Northstate University College of Medicine, Elk Grove

3. Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California Davis, Davis, CA, USA

Abstract

Internal distraction devices are commonly used in congenital micrognathia. The eventual need for device and screw removal can be challenging, requiring extensive dissection and disturbance of bone regenerate. Bioabsorbable poly-L-lactide (PLLA) screws, compared to traditional titanium screws, simplify device removal. Previous in vivo studies have found that the maximal compressive force generated by mandibular distraction is 69.4N. We hypothesized that PLLA screws could support these compressive/distraction forces. Ten mandibles were obtained from 5 canine cadavers. Paired mandibles from the same cadaver were each fixated to a mandibular distractor with eight screws (either titanium or PLLA). Devices were each set to 15 and 30 mm of distraction distance. Compression force of 80 N was then generated parallel to the axis of the distraction device. Distractor displacement was measured to detect any mechanical failure during this pre-set load. Finally, if no failure was observed at 80 N, a load-to-failure compression test was done in the PLLA group to determine the mechanical failure point. All distractors in both the titanium and PLLA screw groups withstood 80 N of compression without failure. When the load-to-failure test was performed in the PLLA group, the average device failure point was 172.8 N (range 148–196 N). Review of high-frame-rate video demonstrated that all failures occurred due to the PLLA screws breaking or falling out. Bioabsorbable PLLA screws can withstand compressive forces more than double that of the maximal in vivo forces needed during mandibular distraction. These screws may be an acceptable alternative for the fixation of internal mandibular distractors.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine,Otorhinolaryngology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3