Flushing and locking management related to central venous catheter occlusion rate among adult patients in acute care: a best practice implementation project

Author:

Fan Chia-Hao12,Chu Chung-Ning3,Chiu Feng-Han4,Chen Chia-Te52,Tung Heng-Hsin2

Affiliation:

1. Department of Nursing, Hualien Tzu Chi Hospital, Hualien, Taiwan

2. College of Nursing, National Yang Ming Chiao Tung University, Taipei, Taiwan

3. Department of Nursing, Hualien Armed Forces General Hospital, Hualien, Taiwan

4. Emergency Department, Hualien Armed Forces General Hospital, Hualien, Taiwan

5. Department of Nursing, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan

Abstract

ABSTRACT Introduction and objectives: A central venous catheter (CVC)—a type of central venous access device (CVAD)—is the most common intervention for critical illnesses. Obstruction of the CVC can lead to fatal consequences. Thus, it is critical to maintain catheter lumen patency. The CVC occlusion rate in a hospital in Taiwan was 33%. This project aimed to decrease the CVC occlusion rate in acute care. Methods: This project was conceptually informed by the JBI Evidence-Based Model of Healthcare, in particular, the conceptualization of evidence implementation as inclusive of context analysis, implementation, and evaluation of outcomes using evidence-based quality indicators. As part of the seven-phase implementation process, we used audit and feedback in a pre- and post-test design to measure baseline compliance. Based on the initial audit, we developed an implementation strategy responsive to the identified gaps in compliance. We then undertook a final audit to measure changes in compliance to evaluate our implementation effects. The JBI software, PACES, and the situational analysis software, GRiP, were used for data collection and implementation planning. There were six evidence-based criteria, with a sample size of 30 nurses for each criterion. The team carried out the project from September 2022 to January 2023. Results: Post-implementation audit compliance rates increased to 100% for the following criteria: the organization had a standardized flushing and locking solution protocol (0%), the CVAD lumen was locked upon completion of the final flush (10%), a single-dose system was used for flushing and locking the CVAD (60%), and preservative-free 0.9% sodium chloride was used to flush the CVAD (60%). Furthermore, the CVC occlusion rate decreased from 33% to 5%. Conclusions: The project successfully decreased the rate of CVC occlusion and increased the competence of nurses in acute care settings. The implementation of best practices in clinical care should focus on leadership, cross-department coordination, education, and innovation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine

Reference17 articles.

1. Normal saline versus heparin for patency of central venous catheters in adult patients: a systematic review and meta-analysis;Zhong;Crit Care,2017

2. Safety and outcomes of midline catheters vs peripherally inserted central catheters for patients with short-term indications: a multicenter study;Swaminathan;JAMA Intern Med,2022

3. Management of occlusion and thrombosis associated with long-term indwelling central venous catheters;Baskin;Lancet,2009

4. Incidence and determinants of port occlusions in cancer outpatients: a prospective cohort study;Milani;Cancer Nurs,2017

5. Interventions for restoring patency of occluded central venous catheter lumens;van Miert;Cochrane Database Syst Rev,2012