The Effect of Inflow Cannula Angle on the Intraventricular Flow Field of the Left Ventricular Assist Device–Assisted Heart: An In Vitro Flow Visualization Study

Author:

May-Newman Karen1,Marquez-Maya Nikolas1,Montes Ricardo1,Salim Saniya1

Affiliation:

1. From the Bioengineering Program, Department of Mechanical Engineering, San Diego State University (SDSU), San Diego, California.

Abstract

Abstract: Previous studies have identified left ventricular assist device (LVAD) inflow cannula (IC) malposition as a significant risk for pump thrombosis. Thrombus development is a consequence of altered flow dynamics, which can produce areas of flow stasis or high shear that promote coagulation. The goal of this study was to measure the effect of IC orientation on the left ventricle (LV) flow field using a mock circulatory loop, and identify flow-based indices that are sensitive measures of cannula malposition. Experimental studies were performed with a customized silicone model of the dilated LV and the EVAHEART Centrifugal LVAS (Evaheart, Inc.; Houston TX). The velocity field of the LV midplane was measured for a transparent IC oriented parallel to and rotated 15° toward the septum under matched hemodynamic conditions. Vortex structures were analyzed and localized stasis calculated within the IC and combined with a map of normalized pulsatile velocity. The velocity fields revealed increased apical stasis and lower pulsatility with a small angulation of the IC. A significant change in vortex dynamics with the angled IC was observed, doubling the size of the counterclockwise (CCW) vortex while reducing the kinetic energy provided by LVAD support. A significant decrease in average and systolic velocities within the IC was found with cannula angulation, suggesting an increased resistance that affects primarily systolic flow and is worsened with increased LVAD support. These common echocardiographic indices offer the opportunity for immediate clinical application during ramp study assessment. Optimized IC positioning may be determined preoperatively using imaging techniques to develop patient-specific surgical recommendations.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.7亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2025 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3