Validation of Visual Prostate Symptom Score (VPSS) in Brazilian Sample Population

Author:

Lopes Maria Helena Baena de MoraesORCID,D'Ancona Carlos Arturo Levi,Moretti Tomás Bernardo Costa,Higa Rosangela,Victal Marcella Lima,Camisão Agnês Raquel,Braga Daniel A.,Reis Leonardo Oliveira

Abstract

PURPOSE: The aim of the study was to evaluate the reliability and validity of the Visual Prostate Symptom Score (VPSS), its correlation with the International Prostate Symptom Score (IPSS), and the time required and need for help when completing the instrument. We also aimed to identify variables associated with difficulty completing these instruments. DESIGN: Longitudinal, prospective correlational study. SUBJECTS AND SETTING: The target population was Brazilian men from different cities within the state of São Paulo with lower urinary tract symptoms followed in urological consultation at a university hospital during October 2017. The sample comprised 59 patients with a mean age of 66.53 years. METHODS: Reliability of the VPSS was evaluated using a test-retest approach and its convergent validity with the IPSS. Cronbach α coefficient was also calculated. Both questionnaires were self-administered and, in case of difficulty of comprehension, assistance was provided. RESULTS: Mean completion time of the IPSS was 6.56 minutes and for VPSS was 5.02 minutes. The variables skin color and educational level were associated with the difficulty in completing the IPSS and for comprehending meaning of the VPSS pictograms. Internal consistency evaluated using Cronbach α coefficient was 0.74 for IPSS and 0.15 for VPSS, respectively. Test-retest reliability testing revealed that both instruments had a high intraclass correlation index (>0.75). There was a significant correlation between the health-related quality of life (QoL) scores of the 2 instruments (0.71, P = .0001) and between the total score of each instrument with its corresponding QoL score. CONCLUSION: Although time for response of the VPSS was shorter and it demonstrated good test-retest reliability, it more frequently required help to answer. The VPSS showed low internal consistency and low correlation with the IPSS (except for the QoL item).

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Medical–Surgical Nursing

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3