Radiological and Dosimetric Evaluation of Biomaterial Composite Phantoms with High Energy Photons and Electrons

Author:

Samson Damilola Oluwafemi,Aziz Mohd Zahri Abdul1,Shukri Ahmad2,Mat Jafri Mohd Zubir2,Hashim Rokiah3,Zuber Siti Hajar2,Hashikin Nurul Ab. Aziz2,Rabba James Anthony1,Samson Peter Ayoola4,Yusof Mohd Fahmi Mohd5

Affiliation:

1. Advanced Medical and Dental Institute, Universiti Sains Malaysia, 13200 Bertam, Penang, Malaysia

2. School of Physics, Universiti Sains Malaysia, 11800 Penang, Malaysia

3. School of Industrial Technology, Universiti Sains Malaysia, 11800 Penang, Malaysia

4. Department of Chemistry, University of Abuja, 900105 Federal Capital Territory, Abuja, Nigeria

5. School of Health Sciences, Universiti Sains Malaysia, 16150 Kota Bharu, Kelantan, Malaysia.

Abstract

Abstract The current study was undertaken to investigate the radiological and dosimetric parameters of natural product-based composite (SPI/NaOH/IA-PAE/Rhizophora spp.) phantoms. The radiological properties of the phantoms were measured at different gamma energies from Compton scatter of photons through angles of 0, 30, 45, 60, 75, and 90 degrees. Ionization chamber (IC) and Gafchromic EBT3 film dosimeters were employed to evaluate the dosimetric characteristics for photons (6–10 MV) and electrons (6–15 MeV). Radiological property results of the composite phantoms were consistent with good quality compared to those of solid water phantoms and theoretical values of water. Photon beam quality index of the SPI15 phantom with p-values of 0.071 and 0.073 exhibited insignificant changes. In addition, good agreement was found between PDD curves measured with IC and Gafchromic EBT3 film for both photons and electrons. The computed therapeutic and half-value depth ranges matched within the limits and are similar to those of water and solid water phantoms. Therefore, the radiological and dosimetric parameters of the studied composite phantom permit its use in the selection of convenient tissue- and water-equivalent phantom material for medical applications.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Health, Toxicology and Mutagenesis,Radiology, Nuclear Medicine and imaging,Epidemiology

Reference33 articles.

1. Radiation shielding of concrete containing zeolite;Radiat Meas,2010

2. AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams;Med Phys,1999

3. Diagnostic reference levels (DRLs) and image quality evaluation for digital mammography in a Nigerian facility;J Nig Soc Phys Sci,2022

4. Composite gelatin/Rhizophora spp. particleboards/PVA for soft tissue phantom applications;Radiat Phys Chem,2020

5. High alloyed new stainless steel shielding material for gamma and fast neutron radiation;Nucl Eng Technol,2020

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3