Affiliation:
1. Department of Ultrasound, Affiliated Hospital of Inner Mongolia University for the Nationalities, Tongliao 028000, China.
Abstract
To investigate the value and accuracy of prenatal GE-E10 ultrasound Equipment in predicting fetal abnormal development. 160 pregnant women and women who received prenatal ultrasound examination were selected. Before delivery, all pregnant women were examined by conventional two-dimensional and four-dimensional (4D) ultrasound. 18 fetuses with abnormal development were detected by gold standard in 160 pregnant women. Sensitivity and specificity of two-dimensional color ultrasound in diagnosing fetal abnormal development were 78.38% and 82.60%. The sensitivity and specificity of 4D color ultrasound in diagnosing fetal abnormal development were 81.15% and 83.43%. ROC showed that the AUC (0.873) of 4D color ultrasound was higher than that of two-dimensional color ultrasound (0.827). The diagnostic efficiency of 4D ultrasound is greater. The accuracy, specificity and sensitivity of 4D color ultrasound in the diagnosis of fetal abnormal development is high, and it is valuable for prenatal screening of macrosomia and low birth weight.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Reference18 articles.
1. The accuracy of ultrasound estimation of fetal weight in comparison to birth weight: a systematic review.;Milner;Ultrasound,2018
2. New Israeli sonographic estimated fetal weight growth curves as compared to current birth weight growth curves: on what should diagnosis of intrauterine growth disorders be based?;Sela;Isr Med Assoc J,2018
3. OP16.10: validation of fetal weight estimation using automated fractional limb volume.;Lee;Ultrasound Obstet Gynecol,2019
4. Is the association between pregnancy weight gain and fetal size causal? A re-examination using a sibling comparison design.;Hutcheon;Epidemiology,2018
5. Frequency of low birth weight in term pregnancy and its association with maternal risk factors.;Javed;Rawal Med J,2018