A study of the correlation between total lung volume and the percent of low attenuation volume and PFT indicators in patients with preoperative lung cancer

Author:

Peng Jing1,Zhao Li1,Wang Yasong2,Yang Hanyan1,Wang Han1,Zhang Mingxiong1,Wang Qiongchuan1,Ye Lianhua3,Wang Zhonghui1ORCID

Affiliation:

1. Department of Anesthesiology, The Third Affiliated Hospital of Kunming Medical University (Yunnan Cancer Hospital), Kunming, China

2. Department of Radiology, The Third Affiliated Hospital of Kunming Medical University (Yunnan Cancer Hospital), Kunming, China

3. Department of Thoracic Surgery I, The Third Affiliated Hospital of Kunming Medical University (Yunnan Cancer Hospital), Kunming, China.

Abstract

The objective was to explore the relationships between computed tomography (CT) lung volume parameters and pulmonary function test (PFT) indexes and develop predictive scores to predict PFT indexes in Chinese preoperative patients suspected with lung cancer. Preoperative patients suspected with lung cancer aged 18 years or more and examined by chest CT scan and PET were consecutively recruited from April to August 2020, at Yunnan Cancer Hospital. CT and PET data were selected from medical record. Pearson correlation was used to explore the relationships between CT parameters and PFT indexes. Predictive scores of PFT indexes were developed from unstandardized coefficients of linear regression models of using CT parameters as predictors. The assessments of predictive ability of scores were conducted by receiver operating characteristics curves. A total of 124 preoperative patients suspected with lung cancer participated in this study. Total lung volume significantly correlated with total lung capacity (r = 0.708), residual volume (r = 0.411), forced expiratory volume in one second (FEV1, r = 0.535), forced vital capacity (FVC, r = 0.687), and FEV1/FVC (r = −0.319). Percent of low attenuation volume significantly correlated with total lung capacity (r = 0.200), residual volume (r = 0.215), FEV1 percentage of predictive value (FEV1%, r = −0.204) and FEV1/FVC (r = −0.345). Four predictive scores for FEV1, FEV1%, FEV1/FVC and FVC% were developed. The area under the curve of receiver operating characteristics for FEV1 <2L, FEV1% <80%, FEV1/FVC <80% and FVC% <80% were 0.856, 0.667, 0.749 and 0.715, respectively. A prediction of poor lung function in preoperative patients suspected with lung cancer, using total lung volume and percent of low attenuation volume was possible. The predictive scores should be further evaluated for external validity.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine

Reference25 articles.

1. Epidemiology of lung cancer.;Mao;Surg Oncol Clin N Am,2016

2. Lung cancer 2020: epidemiology, etiology, and prevention.;Bade;Clin Chest Med,2020

3. Lung cancer.;Nasim;Med Clin North Am,2019

4. [Trend analysis on incidence and age at diagnosis for lung cancer in cancer registration areas of China, 2000-2014].;Zhang;Zhonghua Yu Fang Yi Xue Za Zhi,2018

5. Projections in breast and lung cancer mortality among women: a Bayesian analysis of 52 countries worldwide.;Martin-Sanchez;Cancer Res,2018