Mean power output for muscular endurance exercises and maximal oxygen uptake in military young adults

Author:

Lin Gen-Min12ORCID,Tsai Kun-Zhe123,Lee Duck-Chul4,Sui Xuemei5,Lavie Carl J.6

Affiliation:

1. Department of Internal Medicine, Hualien Armed Forces General Hospital, Hualien City, Taiwan

2. Department of Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan

3. Department of Stomatology of Periodontology, Mackay Memorial Hospital, Taipei, Taiwan

4. Department of Kinesiology, Iowa State University, Ames, IA

5. Department of Exercise Science, Arnold School of Public Health, University of South Carolina, Columbia, SC

6. John Ochsner Heart and Vascular Institute, Ochsner Clinical School, The University of Queensland School of Medicine, New Orleans, LA.

Abstract

The American Heart Association recommends a cardiopulmonary exercise test (CPET) and some alternative exercise tests to evaluate maximal oxygen uptake (VO2 max) of youth. Power output has shown a high correlation with VO2 max on a CPET. However, the correlations between mean power output (MPO) for muscular endurance exercises and VO2 max measured from a CPET are not established in young adults. Forty-five volunteers, with an average age of 29.93 ± 7.05 years, from a sample of 1120 military personnel in Taiwan who attended a 2-minute pushup test and a 2-minute sit-up test were included in the current study. These volunteers subsequently underwent a CPET using the Bruce protocol to assess VO2 max. According to the physics rule, MPO (watts) for the muscular endurance test was defined as a product of moving distance and force: [1/5 × body height (m) × numbers performed × body mass (kg) × gravity (9.8 m/s2)]. Pearson correlation analyses were performed. For the 2-min pushups, the correlations (r) between pushup numbers and VO2 max with and without body mass adjustment were 0.541 (P < .01) and 0.188 (P = .21), respectively, while the correlation (r) between MPO and VO2 max with and without body mass adjustment were 0.410 and 0.557 (both P < .01), respectively. For the 2-minute sit-ups, the correlations (r) between sit-up numbers and VO2 max with and without body mass adjustment were 0.529 (P < .01) and 0.291 (P = .052), respectively, while the correlations (r) between MPO and VO2 max with and without body mass adjustment were 0.318 (P = .03) and 0.705 (P < .01), respectively. In military young adults, MPO for both the 2-minute sit-up and the 2-minute pushup tests could be used as alternative field-based methods to estimate VO2 max.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3