Correlation between serum iron levels and pulmonary function: A cross-sectional analysis based on NHANES database 5319 cases

Author:

Su Lang1ORCID,Hu Sheng1,Wang Silin1,Guo Qiang1,Wei Yiping1

Affiliation:

1. Department of Thoracic Surgery, The Second Affiliated Hospital of Nanchang University, Nanchang, China.

Abstract

Pulmonary function, one of the main indicators of respiratory system assessment, is difficult to measure in specific cases. The study investigated the association between serum iron levels and pulmonary function. The cross-sectional study was conducted using data from 5319 participants from the 2010–2012 National Health and Nutrition Examination Survey. Forced expiratory volume in 1 second (FEV1), forced vital capacity (FVC), and forced expiratory flow from 25% to 75% of FVC were used as indicators of pulmonary function to analyze the relationship of serum iron and pulmonary function. Univariate and stratified analyses, multiple equation regression analysis, smoothed curve fitting analysis, and threshold effect analysis were performed to explore the relationship between pulmonary function and serum iron concentrations. Threshold effect analysis revealed a nonlinear relationship between serum iron levels and FVC, as well as FEV1, with inflection points observed at 8.1 (µmol/L) and 8.4 (µmol/L), respectively. When serum iron concentrations fell below the inflection point, there was no statistically significant relationship between serum iron and FVC (P = .065) or FEV1 (P = .095) (P > .005). However, when serum iron concentrations exceeded the inflection point, both FVC (β = 6.87; 95% confidence interval [CI] = 3.95, 9.79; P < .0001) and FEV1 (β = 7.09; 95% CI = 4.54, 9.64; P < .0001) exhibited a positive correlation with increasing serum iron levels. Additionally, forced expiratory flow from 25% to 75% of FVC (mL/s) demonstrated a positive association with serum iron (β = 6.72; 95% CI = 2.30, 11.13; P = .0029). Serum iron level was positively correlated with pulmonary function within a certain range of serum iron concentration. Serum iron level may be a protective factor for pulmonary function.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine

Reference41 articles.

1. Pulmonary function tests for the generalist: a brief review.;Dempsey;Mayo Clin Proc,2018

2. Current practice in pulmonary function testing.;Evans;Mayo Clin Proc,2003

3. [Spirometry - basic examination of the lung function].;Kociánová;Vnitr Lek,2018

4. [Problems of lung function testing in the laboratory].;Tojo;Rinsho Byori,2006

5. Value of arterial blood gas analysis in patients with acute dyspnea: an observational study.;Burri;Crit Care,2011

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3