Radiation shielding effects of lead equivalent thickness of a radiation protective apron and distance during C-arm fluoroscopy-guided pain interventions: A randomized trial

Author:

Kim Cho Long12,Jeong Hae Chang3,Kim Jae Hun3ORCID

Affiliation:

1. Department of Anesthesiology and Pain Medicine, Hanyang University Hospital, Seoul, Republic of Korea

2. Department of Clinical Science, Konkuk University Graduate School of Medicine, Konkuk University School Seoul, Seoul, Republic of Korea

3. Department of Anesthesiology and Pain Medicine, Konkuk University School of Medicine, Seoul, Republic of Korea.

Abstract

Background: The present study aimed to evaluate the degree of radiation shielding effects according to lead equivalent thickness and distance during C-arm fluoroscopy-guided lumbar interventions. Methods: The exposure time and air kerma were recorded using a fluoroscope. The effective dose (ED) was measured with and without the shielding material of the lead apron using 2 dosimeters at 2 positions. According to the lead equivalent thickness of the shielding material and distance from the side of the table, the groups were divided into 4 groups: group 1 (lead equivalent thickness 0.6 mm, distance 0 cm), group 2 (lead equivalent thickness 0.6 mm, distance 5 cm), group 3 (lead equivalent thickness 0.3 mm, distance 0 cm), and group 4 (lead equivalent thickness 0.3 mm, distance 5 cm). Mean differences such as air kerma, exposure time, ED, and ratio of EDs (ED with protector/ED without protector) were analyzed. Results: A total of 400 cases (100 cases in each group) were collected. The ratio of ED was significantly lower in groups 1 and 2 (9.18 ± 2.78% and 9.56 ± 3.29%, respectively) when compared to that of groups 3 and 4 (21.93 ± 4.19% and 21.53 ± 4.30%, respectively). The reductive effect of a 5-cm distance was 33.3% to 36.1% when comparing the ED between groups 1 and 2 and groups 3 and 4. Conclusions: The 0.3- and 0.6-mm lead equivalent thickness protectors have a radiation attenuation effect of 78.1% to 78.5% and 90.4% to 90.8%, respectively. The 5-cm distance from the side of the table reduces radiation exposure by 33.3% to 36.1%.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine