Serum Titanium Levels Remain Elevated But Urine Titanium is Undetectable in Children With Early Onset Scoliosis Undergoing Growth-Friendly Surgical Treatment: A Prospective Study

Author:

Shams Kameron1,Jha Sahil2,Swallow Jennylee2,Caird Michelle S.2,Farley Frances A.3,Stepanovich Matthew2,Li Ying2

Affiliation:

1. Department of Orthopaedic Surgery, University of Michigan

2. Department of Orthopaedic Surgery, C.S. Mott Children’s Hospital, Michigan Medicine, Ann Arbor, MI

3. Shriners Hospitals for Children, Tampa, FL

Abstract

Background: Elevated serum titanium levels have been found in patients with early onset scoliosis (EOS) treated with traditional growing rods (TGR), magnetically controlled growing rods (MCGR), and vertical expandable prosthetic titanium rib (VEPTR). No studies have investigated whether serum titanium remains persistently elevated and if titanium is excreted. Our purpose was to compare serum titanium levels in patients with EOS with growth-friendly instrumentation to age-matched controls and evaluate urine titanium and serial serum titanium levels in patients with EOS. Methods: This was a prospective case-control study. Patients with EOS with TGR, MCGR, or VEPTR underwent urine titanium and serial serum titanium collection at a minimum 6-month interval. Control patients did not have a history of metal implant insertion and underwent serum titanium collection before fracture fixation. Results: Twenty patients with EOS (6 TGR, 8 MCGR, and 6 VEPTR) and 12 controls were analyzed. The control group had no detectable serum titanium (0 ng/mL), whereas the patients with EOS had a median serum titanium of 4.0 ng/mL (P < 0.001). Analysis of variance showed significantly higher median serum titanium levels in the MCGR and VEPTR groups than the TGR group at time point 1 (5.5 vs 6.0 vs 2.0 ng/mL, P = 0.01) and time point 2 (6.5 vs 7.5 vs 2.0 ng/mL, P < 0.001). Binary comparisons showed a significant difference in serum titanium level between TGR and MCGR (time point 1: P = 0.026, time point 2: P = 0.011) and TGR and VEPTR (time point 1: P = 0.035, time point 2: P = 0.003). However, there was no difference between MCGR and VEPTR (time point 1: P = 0.399, time point 2: P = 0.492) even though the VEPTR group had a longer duration of follow-up (P = 0.001) and a greater number of lengthenings per patient at the first serum collection (P = 0.016). No patients with EOS had detectable urine titanium. Conclusions: Patients with EOS treated with titanium alloy growth-friendly instrumentation had elevated serum titanium levels compared with age-matched controls that persisted over time with no evidence of renal excretion. Additional studies are necessary to assess for local and systemic accumulation of titanium and the significance of long-term exposure to titanium in growing children. Level of Evidence: Level III, therapeutic.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Orthopedics and Sports Medicine,General Medicine,Pediatrics, Perinatology and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3