Test–retest reliability of contrast visual acuities in a clinical population

Author:

Sukha Anusha Y.,Rubin Alan

Abstract

Background: Previously, contrast visual acuities (VA) have been evaluated as a potential screening, diagnostic and predictive tool in cases where standard visual acuity remains intact. Issues around contrast acuity sometimes make it difficult for clinicians to make appropriate clinical decisions and thus such tests have to be standardised and reliable.Aim: To investigate test–retest reliability of contrast VA in healthy adults in a clinical setting.Methods: Best compensated contrast VA at 100%, 10%, 5% and 2.5% of 155 patients (mean age 39.7 ± 12.2 years) were measured using the computerised Thomson Test Chart 2000 Expert. For all participants and at each contrast level, two measurements per right eye were determined. Test–retest reliability for the four contrast levels were assessed using reliability coefficients and Bland–Altman plots. Participants were also divided into three age groups of young (18–39 years, n = 72), middle-age (40–49 years, n = 45) and elderly (50–67 years, n = 38) and reliability was assessed within and between age and gender groups.Results: For the whole-sample test and retest, measurements within each contrast level were not statistically different (p ≥ 0.05). Thus, test and retest measurements per participant were averaged and whole-sample mean-contrast VA and standard deviations for 100%, 10%, 5% and 2.5% were -0.146 ± 0.060, 0.050 ± 0.071, 0.135 ± 0.079 and 0.405 ± 0.115 logMAR, respectively. Significant differences were found between all pairs of contrast levels compared (p ≤ 0.0125). Mean-contrast VA within each age group were also significantly different across all contrast levels (p < 0.0001). Mean-contrast VA at each contrast level between the age groups indicated that mean-contrast VA were not significantly different between the young and middle-age groups (p > 0.05) but were statistically different between the young and elderly groups (p < 0.01). Only mean-contrast VA 10% was significantly different between the middle-age and elderly groups (p < 0.001). Also, mean-contrast VA for the four contrast levels within gender were significantly different (p ≤ 0.05) but not between genders (p ≥ 0.05).Conclusion: This study found good reliability of test and retest measurements of contrast VA in an adult clinical population.

Publisher

AOSIS

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3