Comparison of AirAngel® vs Storz® videolaryngoscope and Macintosh® laryngoscope for endotracheal intubation training: Prospective randomized crossover study

Author:

Merter Şeyhmus1,Kayayurt Kamil1,Kitapçıoğlu Dilek1,Yaylaci Serpil1

Affiliation:

1. Acıbadem University

Abstract

Abstract Background: Video laryngoscopy (VL) outperforms direct laryngoscopy (DL) in both normal and difficult airway situations. However, VL seems far from being offered as a standard option in both healthcare delivery and educational activities in low-income countries, considering its high costs. Therefore, three dimensional (3D)-printed VLs may be considered an alternative to conventional VLs in low-income countries and other places with limited resources. Our objective was to compare the efficacy of AirAngel 3D-printed VL (3D-PVL) with those of commercially available Storz® VL (SVL) and conventional Macintosh® laryngoscope (MCL) in normal and difficult airway scenarios in the hands of inexperienced users. Methods: This is a prospective randomized crossover manikin study that included 126 senior medical students with no experience in intubation. The effectiveness of all three laryngoscopy devices in the hands of inexperienced users was evaluated in terms of intubation time, glottic visualization, ease of use, endotracheal tube placement and intubation success rate. Between 2020 and 2022, 126 last year medical students participated in the study. Results: MCL resulted in significantly longer intubation times than 3D-PVL and SVL in the difficult airway scenario, with no significant difference between 3DPVL and SVL (Wilcoxon test, p < 0.016; Bonferroni correction MCL: 28.54 s; SVL: 26.68 s; 3DPVL: 26.64 s). Both SVL and 3D-PVL resulted in significantly better Cormack−Lehane grades in both normal and difficult airway scenarios, and thus provided better glottic viewing than MCL, with no significant difference between 3D-PVL and SVL (Wilcoxon test, p < 0.016; Bonferroni correction, MCL: 1.73; SVL: 1.29; 3DPVL: 1.25). SVL was the easiest (1: very easy, 5: very difficult) device for normal airway scenarios, while MCL was the most difficult (MCL: 2.64; 3DPVL: 1.98; SVL: 1.49). Conversely, no significant difference was found between 3DPVL and other devices in terms of ease of use in difficult airway scenarios and in terms of accurate placement of the endotracheal tube and successful intubation attempts. Conclusion: 3D-PVL is a good educational and possible clinical alternative to conventional VL, particularly in places with limited resources, due to its low cost.

Publisher

Research Square Platform LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3