Magnetic resonance enterography has high diagnostic accuracy in detecting fibrotic bowel strictures in Crohn’s Disease——A systematic review and meta-analysis

Author:

Zhou Min Si1,Xu Chen Yue1,Dang Yan1,Li Peng1,Xu Li Xue2,Wu Jing1,Shi Hai Yun1

Affiliation:

1. Department of Gastroenterology, Beijing Friendship Hospital, Capital Medical University, National Clinical Research Center for Digestive Diseases

2. Department of Radiology, Beijing Friendship Hospital, Capital Medical University, 95 Yong’an Road, Beijing, China.

Abstract

Abstract Background and Aims Magnetic resonance enterography (MRE) has been reported to identify intestinal strictures in Crohn's disease (CD) patients, and the diagnostic accuracy of MR techniques in differentiating fibrotic from inflammatory strictures remains unclear. This systematic review and meta-analysis was conducted to evaluate the diagnostic performance of current modes of MRE parameters for the detection of fibrosis in stricture lesions of CD patients. Methods A systematic search of EMBASE and MEDLINE up to Nov 2022 identified studies examining the diagnostic accuracy of MRE in the detection of fibrotic strictures in CD patients, using histology as the reference standard. Data was pooled using a bivariate random-effects model to estimate the diagnostic efficiency of fibrotic strictures. Results The final analysis included 17 studies, involving 1012 stricture lesions of 544 CD patients. MRE had a pooled sensitivity of 93% (95% CI: 86%-97%) and specificity of 89% (95% CI: 82%-93%) for the diagnosis of fibrotic strictures. AUC for the detection of fibrosis was 95% (95% CI: 93%-97%). The specificity significantly increased when the diagnosis was conducted per patient (98%; 95%CI: 95%-100%) rather than per segment (84%; 95%CI:80%-88%; P = 0.01). The application of novel MR analytic parameters could significantly improve the sensitivity of MRE in the diagnosis of fibrous stenosis, compared with conventional MRE imaging (P < 0.01). Conclusions MRE has shown excellent potential in the detection of fibrotic strictures in CD patients, with outstanding diagnostic sensitivity and specificity. The application of novel MR analytic parameters could improve the sensitivity of MRE in the diagnosis of fibrous stenosis.

Publisher

Research Square Platform LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3