The pedicle screw accuracy using a robotic system and measured by a novel 3-dimensional method

Author:

Oppermann Marcelo1,Karapetyan Vahagan1,Gupta Shaurya2,Ramjist Joel2,Oppermann Priscila1,Yang Victor XD1

Affiliation:

1. Western University

2. Toronto Metropolitan University

Abstract

Abstract Robotics in medicine is associated with precision, accuracy, and replicability. Several robotic systems are used in spine surgery. They are all considered shared-control systems, providing "steady-hand" manipulation instruments. Although numerous studies have testified to the benefits of robotic instrumentations, they must address their true accuracy. Our study used the Mazor system under several situations and compared the spatial accuracy of the pedicle screw (PS) insertion and its planned trajectory. We used two cadaveric specimens with intact spinal structures from C7 to S1. PS planning was performed using the two registration methods (preopCT/C-arm or CT-to-fluoroscopy registration). After planning, the implant spatial orientation was defined based on six anatomic parameters using axial and sagittal CT images. Two surgical open and percutaneous access were used to insert the PS. After that, another CT acquisition was taken. Accuracy was classified into optimal, inaccurate and unacceptable according to the degree of screw deviation from its planning using the same spatial orientation method. Based on the type of spatial deviation, we also classified the PS trajectory into 16 pattern errors. Seven (19%) out of 37 implanted screws were considered unacceptable (deviation distances >2.0 mm or angulation >5°), and 14 (38%) were inaccurate ( >0.5 mm and ≤ 2.0 mm or >2.5º and ≤ 5º). CT-to-fluoroscopy registration was superior to preopCT/C-arm (average deviation in 0.9mm vs. 1.7mm, respectively, p<0.003), and percutaneous was slightly better than open but did not reach significance (1.3mm vs. 1.7mm, respectively). Regarding pattern error, the tendency was to have more axial than sagittal shifts. Using a quantitative method to categorize the screw 3D position, only 10.8% of the screws were considered unacceptable. However, with a more rigorous concept of inaccuracy, almost half were non-optimal. We also identified that, unlike some previous results, the O-arm registration delivers more accurate implants than the preopCT/C-arm method.

Publisher

Research Square Platform LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3