Performance of a novel 8-color flow cytometry panel in the detection of minimal residual disease assessment of chronic lymphocytic leukemia

Author:

Chen Xiao1,Zhao Sishu1,Shi Yu1,Zhang Ninghan1,Guo Zhen1,Qiao Chun1,Jin Huimin1,Zhu Liying1,Zhu Huayuan1,Li Jianyong1,Wu Yujie1

Affiliation:

1. the First Affiliated Hospital of Nanjing Medical University, Jiangsu Province Hospital

Abstract

Abstract Background The status of minimal residual disease (MRD) has been established as an important prognostic indicator in chronic lymphocytic leukemia (CLL). Methods Owing to the requirements of high accuracy, reproducibility and comparability of MRD, this study investigated the performance of a flow cytometric approach (CD45-ROR1 panel) in the MRD detection of CLL patients, with European Research Initiative on CLL (ERIC) 8-color panel as the “gold standard”. Results The sensitivity, specificity and concordance rate of CD45-ROR1 panel in the MRD assessment of CLL were 100% (87/87), 88.5% (23/26) and 97.3% (110/113), respectively. Two of the 3 non-consistent samples were further verified by the next-generation sequencing. In addition, the MRD results obtained from the CD45-ROR1 panel were positively associated with the ERIC 8-color results for MRD assessment (R = 0.98, p < 0.0001). MRD detection at low levels (≤ 1.0%) demonstrated a smaller difference between the two methods (bias, -0.11; 95% CI, -0.90-0.68) as compared with that at high levels (>0.1%). For the reproducibility assessment, the bias was smaller at three datapoints in the CD45-ROR1 panel as compared with that of the ERIC 8-color panel. Moreover, MRD level detected using the CD45-ROR1 panel for the same samples between different laboratories showed a strong statistical correlation (R = 0.99, p < 0.0001) with a trivial inter-laboratory variation (bias, 0.135; 95% CI, -0.439-0.709). Interesingly, the MRD level detected in the lymph nodes samples were significantly higher than that of the peripheral blood and bone marrow samples (p = 0.029). Conclusions Collectively, this study demonstrates that the CD45-ROR1 panel is a reliable method for the MRD assessment of CLL, with higher sensitivity, reproducibility, and reliability.

Publisher

Research Square Platform LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3