Affiliation:
1. Guilan University of Medical Sciences
Abstract
Abstract
Purpose
To assess the maxillary and mandibular donor sites on cone-beam computed tomography (CBCT) images using Mimics software.
Methods
This cross-sectional study was conducted on 80 CBCT scans. Data in DICOM format were transferred to Mimics software version 21, and a maxillary and a mandibular mask according to cortical and cancellous bones were virtually created for each patient based on Hounsfield units (HUs). Three-dimensional models were reconstructed, boundaries were defined for donor sites including mandibular symphysis, ramus, and coronoid process, zygomatic buttress, and maxillary tuberosity, and virtual osteotomy was conducted on the 3D models to harvest bone. The volume, thickness, width, and length of harvestable bone from each site were quantified by the software. Data were analyzed by independent t-test, one-way ANOVA, and Tukey’s test (alpha = 0.05).
Results
The greatest difference in harvestable bone volume and length was observed between ramus and tuberosity (P < 0.001). The maximum and minimum harvestable bone volumes were found in symphysis (1753.54 mm3) and tuberosity (84.99 mm3). The greatest difference in width and thickness was noted between the coronoid process and tuberosity (P < 0.001), and symphysis and buttress (P < 0.001), respectively. Harvestable bone volume from tuberosity, length, width and volume from symphysis, and volume and thickness from the coronoid process were significantly greater in males (P < 0.05).
Conclusion
The harvestable bone volume was the highest in symphysis followed by ramus, coronoid, buttress, and tuberosity. The harvestable bone length and width was the highest in symphysis and coronoid process, respectively. Maximum harvestable bone thickness was found in symphysis.
Publisher
Research Square Platform LLC
Reference13 articles.
1. Evaluation of volumetry and density of mandibular symphysis bone grafts by three-dimensional computed tomography;Yavuz MS;Dental Traumatology,2009
2. Bone quality and quantity of the mandibular symphyseal region in autogenous bone grafting using cone-beam computed tomography: a cross-sectional study;Safi Y;Head & Face Medicine,2021
3. Evaluation of bone availability for grafts in different donor sites, through computed tomography;GUIMARÃES GMMdF, Bernini GF;Journal of Applied Oral Science,2020
4. Treatment outcome following use of the erbium, chromium:yttrium, scandium, gallium, garnet laser in the non-surgical management of peri-implantitis: a case series;Al-Falaki R;Br Dent J,2014
5. Evaluation of survival and success rates of dental implants reported in longitudinal studies with a follow-up period of at least 10 years: a systematic review;Moraschini V;Int J Oral Maxillofac Surg,2015