Agreement between Capillary Refill Time measured at Finger and Earlobe sites in different positions: a pilot prospective study on healthy volunteers

Author:

Via Luigi La1,Sanfilippo Filippo1,Continella Carlotta1,Triolo Tania1,Messina Antonio2,Robba Chiara3,Astuto Marinella1,Hernandez Glenn4,Noto Alberto5

Affiliation:

1. Azienda Ospedaliero Universitaria “Policlinico – San Marco”

2. Humanitas Clinical and Research Center-IRCCS

3. San Martino Policlinico Hospital, IRCCS for Oncology and Neurosciences

4. Pontificia Universidad Católica de Chile

5. University of Messina, Policlinico "G. Martino"

Abstract

Abstract Background: Capillary Refill Time (CRT) is a marker of peripheral perfusion usually performed at fingertip; however, its evaluation at other sites/position may be advantageous. Moreover, arm position during CRT assessment has not been fully standardized. Methods: We performed a pilot prospective observational study in 82 healthy volunteers. CRT was assessed: a) in standard position with participants in semi-recumbent position; b) at 30° forearm elevation, c and d) at earlobe site in semi-recumbent and supine position. Bland-Altman analysis was performed to calculate bias and limits of agreement (LoA). Correlation was investigated with Pearson test. Results: Standard finger CRT values (1.04 sec [0.80;1.39]) were similar to the earlobe semi-recumbent ones (1.10 sec [0.90;1.26]; p=0.52), with Bias 0.02±0.18 sec (LoA -0.33;0.37); correlation was weak but significant (r=0.28 [0.7;0.47]; p=0.01). Conversely, standard finger CRT was significantly longer than earlobe supine CRT (0.88 sec [0.75;1.06]; p<0.001) with Bias 0.22±0.4 sec (LoA -0.56;1.0), and no correlation (r=0,12 [-0,09;0,33]; p=0.27]. As compared with standard finger CRT, measurement with 30° forearm elevation was significantly longer (1.17 sec [0.93;1.41] p=0.03), with Bias -0.07±0.3 sec (LoA -0.61;0.47) and significant correlation of moderate degree (r=0.67 [0.53;0.77; p<0.001). Conclusions: In healthy volunteers, the elevation of the forearm significantly prolongs CRT values. CRT measured at the earlobe in semi-recumbent position may represent a valid surrogate when access to the finger is not feasible, whilst earlobe CRT measured in supine position yields different results. Research is needed in critically ill patients to evaluate accuracy and precision at different sites/positions.

Publisher

Research Square Platform LLC

Reference28 articles.

1. Capillary refill time in adults;Lewin J;Emerg Med J,2008

2. Macrocirculatory and Microcirculatory Endpoints in Sepsis Resuscitation;Mok G,2021

3. Optimal target in septic shock resuscitation;Reardon P;J Intensive Care Med,2020

4. Monitoring the microcirculation in the critically ill patient: current methods and future approaches;Backer D;Intensive Care Med,2010

5. Optical Fibre Sensor for Capillary Refill Time and Contact Pressure Measurements under the Foot;Ballaji HK,2021

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3