Influence of the orientation of constructed blood vessels during the 3D printing on the measurement of the pseudo-oxygen saturation of an artificial blood substitute using conventional oxygen sensors: a test series

Author:

Jung Svenja1,Hoffmann Martin1,Winkler Dirk1,Güresir Erdem1,Kropla Fabian1,Scholz Sebastian2,Grunert Ronny1

Affiliation:

1. University of Leipzig Medical Center

2. Fraunhofer Plastics Technology Center Oberlausitz

Abstract

Abstract Background: The development of phantoms to reduce animal testing or to validate new instruments or operation techniques is of increasing importance. On this account, a blood circulation-phantom was developed and used to evaluate conventional oxygen sensors for a newly developed spatula for direct measurement of the blood oxygen saturation at the parenchyma. Methods: A solution of copper and nickel sulfate was used as blood substitute. A total of seven different solutions with a pseudo-saturation between 50 % and 100 % were created. To evaluate the solution as a suitable blood substitute, a two-stage feasibility study was conducted. This study consisted of capturing the absorption spectra of the two sulfate solutions and calibrating the used oxygen sensor. Additionally, blood vessels with a simplified geometry were designed and manufactured using an elastic material (Elastic 50A) with a 3D printer (Formlabs Form 2). To determine the orientation during the printing process, various vessels were printed. Measurements to assess the effects of disturbance (rotation of the vessels during measurements) on the sensor readouts were prepared. Results: Upon analyzing the absorption spectra of the blood substitute and ordinary blood, it was observed that the components of the solution behaved similarly to oxygenated and deoxygenated blood, confirming the suitability of copper and nickel sulfate as a blood substitute. The impact of disturbances was also verified through the rotation of the 3D-printed vessels. It was shown that a measurement directly on the disturbances led to outliers and higher values. An optimal orientation was determined to be a lateral placement (90° or 270°) of the sensor. Regarding the orientation of the vessels within the printing space, an orientation of 45° yielded the best results, as the individual layers least affected the light emitted and received by the oxygen sensor. All results pertain to constructed vessels developed using a Formlabs Form 2 printer and Elastic 50A material by Formlabs. Conclusion: The achieved results demonstrate the influence of the orientation of the vessel during 3D printing as well as the influence of the position of the vessel during the measurement using a conventional oxygen sensor.

Publisher

Research Square Platform LLC

Reference29 articles.

1. Bundesinstitut für Risikobewertung. (2022) Verwendung von Versuchstieren im Jahr 2021 [Use of laboratory animals in 2021]. https://www.bf3r.de/de/verwendung_von_versuchstieren_im_jahr_2021-309160.html.

2. Deutscher Tierschutzbund. (2023) Statistik zu Tierversuchen [Animal testing statistic]. https://www.tierschutzbund.de/tiere-themen/tierversuche/statistik-zu-tierversuchen.

3. 3D printed patient-specific thorax phantom with realistic heterogenous bone radiopacity using filament printer technology;Hatamikia S;Z Med Phys,2022

4. Anthropomorphic optical phantom of the neonatal thorax: a key tool for pulmonary studies in preterm infants;Pacheco Tobo AL;J Biomed Opt,2020

5. A moving liver phantom in an anthropomorphic thorax for SPECT MP imaging;Panagi S;Phys Eng Sci Med,2022

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3