Experimental verification of gamma-efficiency calculations for scintillation detectors in ANGLE 4 software

Author:

Thabet Abouzeid1,Dlabac Aleksandar2,Jovanovic Slobodan3,Badawi Mohamed4,Mihaljevic Nikola5,El-Khatib Ahmed4,Gouda Mona4,Abbas Mahmoud4

Affiliation:

1. Pharos University, Faculty of Allied Medical Sciences, Department of Medical Equipment Technology, Alexandria, Egypt

2. University of Montenegro, Centre for Nuclear Competence and Knowledge Management, Podgorica, Montenegro

3. University of Montenegro, Centre for Nuclear Competence and Knowledge Management, Podgorica, Montenegro + University of Montenegro, Faculty of Mathematics and Natural Sciences, Department of Physics, Podgorica, Montenegro

4. Alexandria University, Faculty of Science, Department of Physics, Alexandria, Egypt

5. University of Montenegro, Centre for Nuclear Competence and Knowledge Management, Podgorica, Montenegro + University of Montenegro, Maritime Faculty, Department of Mathematics, Kotor, Montenegro

Abstract

ANGLE software for semiconductor detector efficiency calculations - long existing and widely accepted tool in quantitative gamma spectrometry - has been recently extended to scintillation NaI detectors. The extension features in the latest edition (ANGLE 4) and it is briefly outlined. Discretization of reference efficiency curve, meaning possibility of using ANGLE 4 for particular gamma energies without constructing the complete reference efficiency curve, is particularly emphasized. This yields both in enhanced practicality and higher accuracy, while reducing the potential for systematic errors. The present work is primarily focussed on experimental verification of ANGLE 4 for NaI detectors. Two detectors (2 ? 2 and 3 x 3 inches) were employed in the experiment. Commercially calibrated gamma sources (in the forms of quasi point and cylinder) and homemade solutions (diluted from calibrated ones) were measured at various distances from the detector(s), ranging 0 cm to 50 cm. Energy range observed was 59 keV to 1408 keV. Versatility of counting conditions, in terms of detectors and sources used, gamma energies observed, source detector separations, etc., was aimed at creating as large experimental evidence as possible for verification purposes. Experimentally obtained efficiencies are compared with those calculated by ANGLE 4. Very good agreement is obtained - well within the experimental uncertainties - thus proving the reliability of the software.

Publisher

National Library of Serbia

Subject

Safety, Risk, Reliability and Quality,Nuclear Energy and Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3