Abstract OBJECTIVE To determine intra- and interobserver reliability of a fluorescein stain–based tear film breakup time (TFBUT) test as performed in a clinical environment with and without administration of a topical anesthetic. ANIMALS 21 privately owned dogs. PROCEDURES A randomized study design was used. Two independent observers that commonly perform the TFBUT test in clinical practice read the same description of TFBUT. Observers performed TFBUT testing for each dog before and after topical administration of 0.5% proparacaine solution in 4 testing periods with a 1-hour interval between periods. Intraclass correlation coefficient (ICC) analysis was used to assess inter- and intraobserver test reliability. Linear mixed models were used to assess the main effects of testing period, observer, eye, and presence of ophthalmic disorders and their interactions on TFBUT. RESULTS Mean TFBUT measurements performed by observer 1 and observer 2 were 5.9 seconds and 8.6 seconds, respectively, when adjusted for other effects in the model. Intraobserver ICC was poor for one observer and moderate for the other. Interobserver ICC was poor without use of topical anesthetic and slightly lower when anesthetic was used. Observer and testing period were each significantly associated with TFBUT; the measurements decreased and were more variable after multiple applications of fluorescein stain and proparacaine. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested tear film stability is negatively affected by topical administration of 0.5% proparacaine solution and repeated applications of fluorescein stain. The TFBUT test as performed in this study had poor to moderate reliability.

Publisher

American Veterinary Medical Association (AVMA)

Subject

General Veterinary,General Medicine

Reference90 articles.

1. Determination of tear break-up time reference values and ocular tolerance of tetracaine hydrochloride eyedops in healthy horses;Monclin;Equine Vet J.,2011

2. Density and distribution of canine conjunctival goblet cells;Moore;Invest Ophthalmol Vis Sci.,1987

3. The influence of eyelid temperature on the delivery of meibomian oil;Nagymihályi;Exp Eye Res.,2004

4. Keratoconjunctival effects of diabetes mellitus in dogs;Cullen;Vet Ophthalmol.,2005

5. The influence of eyelid temperature on the delivery of meibomian oil;Nagymihályi;Exp Eye Res.,2004

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3