Agreement between oscillometric and direct blood pressure measurements in anesthetized captive chimpanzees (Pan troglodytes)

Author:

Smith Christopher K.1,Ashley Anthony L.1,Zhu Xiaojuan1,Cushing Andrew C.1

Affiliation:

1. 1 From the Department of Small Animal Clinical Sciences (Smith, Cushing) and Office of Information and Technology (Zhu), College of Veterinary Medicine, University of Tennessee, Knoxville, TN 37996; and The Chattanooga Zoo, Chattanooga, TN 37404 (Ashley).

Abstract

Abstract OBJECTIVE To evaluate the level of agreement (LOA) between direct and oscillometric blood pressure (BP) measurements and the ability of oscillometric measurements to accurately detect hypotension in anesthetized chimpanzees (Pan troglodytes). ANIMALS 8 captive, adult chimpanzees. PROCEDURES During prescheduled annual examinations, each chimpanzee underwent general anesthesia and patient monitoring for their examination, echocardiography for a concurrent study, and measurement of direct BP with the use of tibial artery catheterization and oscillometry with the use of a cuff placed around a brachium and a cuff placed around the second digit of the contralateral forelimb for the present study. Bland-Altman plots were generated to compare results for direct and oscillometric BP measurements. Mean bias and 95% LOAs were calculated for oscillometric measurements of systolic arterial pressure (SAP), diastolic arterial pressure (DAP), and mean arterial pressure (MAP) for each cuff site. Sensitivity and specificity in detecting hypotension were also determined for each cuff site. RESULTS There were 74 paired direct and brachial oscillometric measurements of each, SAP, MAP, and DAP and 66 paired direct and digit oscillometric measurements of each, SAP, MAP, and DAP. Only brachial oscillometric measurements of MAP had adequate sensitivity (78%) and specificity (95%) to accurately detect hypotension, and this technique also had the least mean bias (0.8 mm Hg; 95% LOA, –29 to 31 mm Hg). CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that brachial oscillometric measurement of MAP provided reasonable agreement with tibial arterial direct MAP measurement and performed well in diagnosing hypotension in anesthetized chimpanzees.

Publisher

American Veterinary Medical Association (AVMA)

Subject

General Veterinary,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3