Abstract

Background Magnetic resonance imaging (MRI) has been frequently used to determine a preoperative treatment plan for gynecologic cancers. However, the MR accuracy for staging an endometrial cancer is not satisfactory based on the old FIGO staging system. Purpose To evaluate MR accuracy for staging endometrial cancer using the new FIGO staging system. Material and Methods Between January 2005 and May 2009, 199 women underwent surgery due to endometrial cancer. In each patient, an endometrial cancer was staged using MR findings based on the old FIGO staging system and then repeated according to the new FIGO staging system for comparison. Histopathologic findings were used as a standard of reference. Results The accuracy of MRI in the staging of endometrial carcinoma stage I, II, III, and IV using the old FIGO staging system were 80% (159/199), 89% (178/199), 90% (179/199), and 99% (198/199), respectively, compared to 87% (174/199), 97% (193/199), 90% (179/199), and 99% (198/199), respectively, when using the new FIGO staging criteria. The overall MR accuracy of the old and new staging systems were 51% (101/199) and 81% (161/199), respectively. Conclusion MRI has become a more useful tool in the preoperative staging of endometrial cancers using the new FIGO staging system compared to the old one with increased accuracy.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3