Author:
Dyagelev M Y,Isakov V G,Grakhova E V
Abstract
Abstract
The article is dedicated to determine the α-factor of aeration systems in case of changing the wastewater treatment line (transfer of aeration tanks to the nitri-denitrifier aeration mode). The studies were performed on an experimental installation with sewage and activated sludge at one of the sewage treatment facilities of the Udmurt Republic. During the process of determining the parameter under consideration, pure water and the sludge mixture from the experimental plant were sequentially aerated at the same conditions; thus, the K
Lα was sequentially determined for two different types of liquids. The ratio of different liquids defined under the same conditions of K
Lα determines the α-factor. Plate aerators with a dispersing element made of a rubber membrane were used as an experimental plants, thanks to which a high calculated value of the α-factor was found - 0.95 ± 0.03.
Reference21 articles.
1. Materials and Technologies Used in Wastewater Treatment;Moga;IOP Conference Series: Materials Science and Engineering,2018
2. Reduction of energy consumption of wastewater aeration systems;Serpokrilov;Bulletin TGASU,2010
3. Study on low intensity aeration oxygenation model and optimization for shallow water;Chen;IOP Conference Series: Earth and Environmental Science,2018
4. New approaches to enhance pollutant removal in artificially aerated wastewater treatment systems;Freeman;Science of The Total Environment,2018
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献