Rotational disturbance in laser-interferometric gravity gradiometry

Author:

Shiomi SachieORCID

Abstract

Abstract Laser interferometers have been used for precise measurements of gravity and related effects. These include experiments to search for a fifth force and absolute ballistic gravimeters, which use a Michelson-type laser interferometer to measure the acceleration of a free-falling test mass. In these methods of instrumentation, the motion of free-falling test masses is measured using corner-cube laser interferometers, in which at least one retroreflector is embedded in each test mass. However carefully each of such test masses is released into free fall, a small amount of rotation is unavoidable which changes the optical path length and causes acceleration disturbance. This rotational disturbance could ultimately limit the measurement sensitivity of the laser interferometers. Various experimental and theoretical studies have been conducted to minimise the rotational disturbance in absolute ballistic gravimeters. This paper focuses on the rotational disturbance in laser-interferometric gravity gradiometers (LIGGs) that measure differential acceleration between two test masses freely falling at different heights in a vacuum. LIGGs can be configured to measure not only vertical gravity gradients, but also horizontal gradients, or gradients in both horizontal and vertical directions. However, only those to measure vertical gravity gradients have been constructed so far. Hence, in this paper, the term LIGGs specifically indicates the gravity gradiometers that measure vertical gravity gradients. Unlike absolute ballistic gravimeters, the LIGGs are, in principle, insensitive to ground vibrations; they can potentially detect some effects that are buried in seismic noise in absolute gravity data. To fully leverage this advantage of the LIGGs, it is crucial to keep the rotational disturbance to a minimum. Expressions for the rotational disturbance are derived and its magnitude is estimated based on available experimental data. The results show that the magnitude would not be more than 0.1 μ Gal /m in the measurement of vertical gravity gradients in a compact LIGG. Alternative designs and requirements for increasing the sensitivity of the LIGGs are also discussed.

Funder

Japan Society for the Promotion of Science

Publisher

IOP Publishing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3