Calibration strategy of the PROSPECT-II detector with external and intrinsic sources

Author:

Andriamirado M.,Balantekin A.B.,Bass C.D.,Bergeron D.E.,Bernard E.P.,Bowden N.S.,Bryan C.D.,Carr R.,Classen T.,Conant A.J.,Delgado A.,Diwan M.V.,Dolinski M.J.,Erickson A.,Foust B.T.,Gaison J.K.,Galindo-Uribarri A.,Gilbert C.E.,Gokhale S.,Grant C.,Hans S.,Hansell A.B.,Heeger K.M.,Heffron B.,Jaffe D.E.,Jayakumar S.,Ji X.,Jones D.C.,Koblanski J.,Kunkle P.,Lane C.E.,Langford T.J.,LaRosa J.,Littlejohn B.R.,Lu X.,Maricic J.,Mendenhall M.P.,Meyer A.M.,Milincic R.,Mueller P.E.,Mumm H.P.,Napolitano J.,Neilson R.,Nikkel J.A.,Nour S.,Palomino J.L.,Pushin D.A.,Qian X.,Roca C.,Rosero R.,Searles M.,Surukuchi P.T.,Sutanto F.,Tyra M.A.,Venegas-Vargas D.,Weatherly P.B.,Wilhelmi J.,Woolverton A.,Yeh M.,Zhang C.,Zhang X.

Abstract

Abstract This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector, PROSPECT-II (P-II), to advance capabilities for the investigation of fundamental neutrino physics, fission processes and associated reactor neutrino flux, and nuclear security applications. P-II will expand the statistical power of the original PROSPECT (P-I) dataset by at least an order of magnitude. The new design builds upon previous P-I design and focuses on improving the detector robustness and long-term stability to enable multi-year operation at one or more sites. The new design optimizes the fiducial volume by elimination of dead space previously occupied by internal calibration channels, which in turn necessitates the external deployment. In this paper, we describe a calibration strategy for P-II. The expected performance of externally deployed calibration sources is evaluated using P-I data and a well-benchmarked simulation package by varying detector segmentation configurations in the analysis. The proposed external calibration scheme delivers a compatible energy scale model and achieves comparable performance with the inclusion of an additional AmBe neutron source, in comparison to the previous internal arrangement. Most importantly, the estimated uncertainty contribution from the external energy scale calibration model meets the precision requirements of the P-II experiment.

Publisher

IOP Publishing

Subject

Mathematical Physics,Instrumentation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3