Synthetic CT generation from CBCT images via unsupervised deep learning

Author:

Chen Liyuan,Liang Xiao,Shen ChenyangORCID,Nguyen DanORCID,Jiang Steve,Wang JingORCID

Abstract

Abstract Adaptive-radiation-therapy (ART) is applied to account for anatomical variations observed over the treatment course. Daily or weekly cone-beam computed tomography (CBCT) is commonly used in clinic for patient positioning, but CBCT’s inaccuracy in Hounsfield units (HU) prevents its application to dose calculation and treatment planning. Adaptive re-planning can be performed by deformably registering planning CT (pCT) to CBCT. However, scattering artifacts and noise in CBCT decrease the accuracy of deformable registration and induce uncertainty in treatment plan. Hence, generating from CBCT a synthetic CT (sCT) that has the same anatomical structure as CBCT but accurate HU values is desirable for ART. We proposed an unsupervised style-transfer-based approach to generate sCT based on CBCT and pCT. Unsupervised learning was desired because exactly matched CBCT and CT are rarely available, even when they are taken a few minutes apart. In the proposed model, CBCT and pCT are two inputs that provide anatomical structure and accurate HU information, respectively. The training objective function is designed to simultaneously minimize (1) contextual loss between sCT and CBCT to maintain the content and structure of CBCT in sCT and (2) style loss between sCT and pCT to achieve pCT-like image quality in sCT. We used CBCT and pCT images of 114 patients to train and validate the designed model, and another 29 independent patient cases to test the model’s effectiveness. We quantitatively compared the resulting sCT with the original CBCT using the deformed same-day pCT as reference. Structure-similarity-index, peak-signal-to-noise-ratio, and mean-absolute-error in HU of sCT were 0.9723, 33.68, and 28.52, respectively, while those of CBCT were 0.9182, 29.67, and 49.90, respectively. We have demonstrated the effectiveness of the proposed model in using CBCT and pCT to synthesize CT-quality images. This model may permit using CBCT for advanced applications such as adaptive treatment planning.

Funder

Cancer Prevention and Research Institute of Texas

National Institutes of Health

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3