Effects of atlas-based anatomy on modelled light transport in the neonatal head

Author:

Hirvi PauliinaORCID,Kuutela TopiORCID,Fang QianqianORCID,Hannukainen Antti,Hyvönen NuuttiORCID,Nissilä IlkkaORCID

Abstract

Abstract Objective. Diffuse optical tomography (DOT) provides a relatively convenient method for imaging haemodynamic changes related to neuronal activity on the cerebral cortex. Due to practical challenges in obtaining anatomical images of neonates, an anatomical framework is often created from an age-appropriate atlas model, which is individualized to the subject based on measurements of the head geometry. This work studies the approximation error arising from using an atlas instead of the neonate's own anatomical model. Approach. We consider numerical simulations of frequency-domain (FD) DOT using two approaches, Monte Carlo simulations and diffusion approximation via finite element method, and observe the variation in (1) the logarithm of amplitude and phase shift measurements, and (2) the corresponding inner head sensitivities (Jacobians), due to varying segmented anatomy. Varying segmentations are sampled by registering 165 atlas models from a neonatal database to the head geometry of one individual selected as the reference model. Prior to the registration, we refine the segmentation of the cerebrospinal fluid (CSF) by separating the CSF into two physiologically plausible layers. Main results. In absolute measurements, a considerable change in the grey matter or extracerebral tissue absorption coefficient was found detectable over the anatomical variation. In difference measurements, a small local 10%-increase in brain absorption was clearly detectable in the simulated measurements over the approximation error in the Jacobians, despite the wide range of brain maturation among the registered models. Significance. Individual-level atlas models could potentially be selected within several weeks in gestational age in DOT difference imaging, if an exactly age-appropriate atlas is not available. The approximation error method could potentially be implemented to improve the accuracy of atlas-based imaging. The presented CSF segmentation algorithm could be useful also in other model-based imaging modalities. The computation of FD Jacobians is now available in the widely-used Monte Carlo eXtreme software.

Funder

Luonnontieteiden ja Tekniikan Tutkimuksen Toimikunta

Suomalainen Tiedeakatemia

National Institutes of Health

Päivikki ja Sakari Sohlbergin Säätiö

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3