A unified path seeking algorithm for IMRT and IMPT beam orientation optimization

Author:

Ramesh PavitraORCID,Valdes Gilmer,O’Connor DanielORCID,Sheng KeORCID

Abstract

Abstract Objective. Fully automated beam orientation optimization (BOO) for intensity-modulated radiotherapy and intensity modulated proton therapy (IMPT) is gaining interest, since achieving optimal plan quality for an unknown number of fixed beam arrangements is tedious. Fast group sparsity-based optimization methods have been proposed to find the optimal orientation, but manual tuning is required to eliminate the exact number of beams from a large candidate set. Here, we introduce a fast, automated gradient descent-based path-seeking algorithm (PathGD), which performs fluence map optimization for sequentially added beams, to visualize the dosimetric benefit of one added field at a time. Approach. Several configurations of 2–4 proton and 5–15 photon beams were selected for three head-and-neck patients using PathGD, which was compared to group sparsity-regularized BOO solved with the fast iterative shrinkage-thresholding algorithm (GS-FISTA), and manually selected IMPT beams or one coplanar photon VMAT arc (MAN). Once beams were chosen, all plans were compared on computational efficiency, dosimetry, and for proton plans, robustness. Main results. With each added proton beam, Clinical Target Volume (CTV) and organs at risk (OAR) dosimetric cost improved on average across plans by [1.1%, 13.6%], and for photons, [0.6%, 2.0%]. Comparing algorithms, beam selection for PathGD was faster than GS-FISTA on average by 35%, and PathGD matched the CTV coverage of GS-FISTA plans while reducing OAR mean and maximum dose in all structures by an average of 13.6%. PathGD was able to improve CTV [Dmax, D95%] by [2.6%, 5.2%] and reduced worst-case [max, mean] dose in OARs by [11.1%, 13.1%]. Significance. The benefit of a path-seeking algorithm is the beam-by-beam analysis of dosimetric cost. PathGD was shown to be most efficient and dosimetrically desirable amongst group sparsity and manual BOO methods, and highlights the sensitivity of beam addition for IMPT in particular.

Funder

National Institutes of Health

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3