Abstract For the first time, a low-field open magnetic resonance (MR) scanner was combined with a proton pencil beam scanning (PBS) research beamline. The aim of this study was to characterize the magnetic fringe fields produced by the PBS system and measure their effects on MR image quality during simultaneous PBS irradiation and image acquisition. A magnetic field camera measured the change in central resonance frequency (Δf res) and magnetic field homogeneity (ΔMFH) of the B0 field of the MR scanner during operation of the beam transport and scanning magnets. The beam energy was varied between 70 − 220 MeV and beam scanning was performed along the central horizontal and vertical axis of a 48 × 24 cm2 radiation field. The time structure of the scanning magnets’ fringe fields was simultaneously recorded by a tri-axial Hall probe. MR imaging experiments were conducted using the ACR (American College of Radiology) Small MRI Phantom and a spoiled gradient echo pulse sequence during simultaneous volumetric irradiation. Computer simulations were performed to predict the effects of B 0 field perturbations due to PBS irradiation on MR image formation in k-space. Setting the beam transport magnets, horizontal and vertical scanning magnets resulted in a maximum Δf res of 50, 235 and 4 Hz, respectively. The ΔMFH was less than 3 parts per million for all measurements. MR images acquired during beam energy variation and vertical beam scanning showed no visual loss in image quality. However, MR images acquired during horizontal beam scanning showed severe coherent ghosting artefacts in phase encoding direction. Both simulated and measured k-space phase maps prove that these artefacts are caused by phase-offsets. This study shows first experimental evidence that simultaneous in-beam MR imaging during proton PBS irradiation is subject to severe loss of image quality in the absence of magnetic decoupling between the PBS and MR system.

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3