Extracting the gradient component of the gamma index using the Lie derivative method

Author:

Anetai YusukeORCID,Doi KentaroORCID,Takegawa HidekiORCID,Koike YuheiORCID,Nishio TeijiORCID,Nakamura MitsuhiroORCID

Abstract

Abstract Objective. The gamma index (γ) has been extensively investigated in the medical physics and applied in clinical practice. However, γ has a significant limitation when used to evaluate the dose-gradient region, leading to inconveniences, particularly in stereotactic radiotherapy (SRT). This study proposes a novel evaluation method combined with γ to extract clinically problematic dose-gradient regions caused by irradiation including certain errors. Approach. A flow-vector field in the dose distribution is obtained when the dose is considered a scalar potential. Using the Lie derivative from differential geometry, we defined L, S, and U to evaluate the intensity, vorticity, and flow amount of deviation between two dose distributions, respectively. These metrics multiplied by γ (γL, γS, γU), along with the threshold value σ, were verified in the ideal SRT case and in a clinical case of irradiation near the brainstem region using radiochromic films. Moreover, Moran’s gradient index (MGI), Bakai’s χ factor, and the structural similarity index (SSIM) were investigated for comparisons. Main results. A high L-metric value mainly extracted high-dose-gradient induced deviations, which was supported by high S and U metrics observed as a robust deviation and an influence of the dose-gradient, respectively. The S-metric also denotes the measured similarity between the compared dose distributions. In the γ distribution, γL sensitively detected the dose-gradient region in the film measurement, despite the presence of noise. The threshold σ successfully extracted the gradient-error region where γ > 1 analysis underestimated, and σ = 0.1 (plan) and σ = 0.001 (film measurement) were obtained according to the compared resolutions. However, the MGI, χ, and SSIM failed to detect the clinically interested region. Significance. Although further studies are required to clarify the error details, this study demonstrated that the Lie derivative method provided a novel perspective for the identifying gradient-induced error regions and enabled enhanced and clinically significant evaluations of γ.

Funder

Japan Society for the Promotion of Science

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3