Edge effect reduction of high-resolution PET detectors using LYSO and GAGG phoswich crystals

Author:

Liu Zheng,Mungai Samuel,Niu MingORCID,Kuang ZhonghuaORCID,Ren Ning,Wang Xiaohui,Sang ZiruORCID,Yang Yongfeng

Abstract

Abstract Objective. Small-animal positron emission tomography (PET) is a powerful preclinical imaging tool in animal model studies. The spatial resolution and sensitivity of current PET scanners developed for small-animal imaging need to be improved to increase the quantitative accuracy of preclinical animal studies. This study aimed to improve the identification capability of edge scintillator crystals of a PET detector which will enable to apply a crystal array with the same cross-section area as the active area of a photodetector for improving the detection area and thus reducing or eliminating the inter-detector gaps. Approach. PET detectors using crystal arrays with mixed lutetium yttrium orthosilicate (LYSO) and gadolinium aluminum gallium garnet (GAGG) crystals were developed and evaluated. The crystal arrays consisted of 31 × 31 array of 0.49 × 0.49 × 20 mm3 crystals; they were read out by two silicon photomultiplier arrays with pixel sizes of 2 × 2 mm2 that were placed at both ends of the crystal arrays. The second or first outermost layer of the LYSO crystals was replaced by GAGG crystals in the two crystal arrays. The two crystal types were identified using a pulse-shape discrimination technique to provide better edge crystal identification. Main results. Using the pulse shape discrimination technique, almost all (except for a few edge) crystals were resolved in the two detectors; high sensitivity was achieved by using the scintillator array and the photodetector with the same areas and achieved high resolution by using crystals with sizes equal to 0.49 × 0.49 × 20 mm3. Energy resolutions of 19.3 ± 1.8% and 18.9 ± 1.5%, depth-of-interaction resolutions of 2.02 ± 0.17 mm and 2.04 ± 0.18 mm, and timing resolutions of 1.6 ± 0.2 ns and 1.5 ± 0.2 ns were achieved by the two detectors, respectively. Significance. In summary, novel three-dimensional high-resolution PET detectors consisting of a mixture of LYSO and GAGG crystals were developed. The detectors significantly improve the detection area with the same photodetectors and thus improve the detection efficiency.

Funder

National Natural Science Foundation of China

Shenzhen Science and Technology Program

Shenzhen Bay Laboratory

Scientific Instrument Innovation Team of the Chinese Academy of Sciences

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Reference40 articles.

1. Advances in preclinical PET instrumentation;Amirrashedi;PET Clin.,2020

2. The 2006 Henry NWagner lecture: of mice and men (and positrons)—advances in PET imaging technology;Cherry;J. Nucl. Med.,2006

3. Total-body PET: maximizing sensitivity to create new opportunities for clinical research and patient care;Cherry;J. Nucl. Med.,2018

4. Timing evaluation of a PET detector block based on semi-monolithic LYSO crystals;Cucarella;Med. Phys.,2021

5. Performance of a YSO/LSO phoswich detector for use in a PET/SPECT system;Dahlbom;IEEE Trans. Nucl. Sci.,1997

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3