Radiation exposure in augmented fluoroscopic bronchoscopy procedures: a comprehensive analysis for patients and physicians

Author:

Lian Meng-EnORCID,Yee Wong Guang,Yu Kai-Lun,Wu Guan-Yi,Yang Shun-Mao,Tsai Hui-YuORCID

Abstract

Abstract Cancer is a major health challenge and causes millions of deaths worldwide each year, and the incidence of lung cancer has increased. Augmented fluoroscopic bronchoscopy (AFB) procedures, which combine bronchoscopy and fluoroscopy, are crucial for diagnosing and treating lung cancer. However, fluoroscopy exposes patients and physicians to radiation, and therefore, the procedure requires careful monitoring. The National Council on Radiation Protection and Measurement and the International Commission on Radiological Protection have emphasised the importance of monitoring patient doses and ensuring occupational radiation safety. The present study evaluated radiation doses during AFB procedures, focusing on patient skin doses, the effective dose, and the personal dose equivalent to the eye lens for physicians. Skin doses were measured using thermoluminescent dosimeters. Peak skin doses were observed on the sides of the patients’ arms, particularly on the side closest to the x-ray tube. Differences in the procedures and experience of physicians between the two hospitals involved in this study were investigated. AFB procedures were conducted more efficiently at Hospital A than at Hospital B, resulting in lower effective doses. Cone-beam computed tomography (CT) contributes significantly to patient effective doses because it has higher radiographic parameters. Despite their higher radiographic parameters, AFB procedures resulted in smaller skin doses than did image-guided interventional and CT fluoroscopy procedures. The effective doses differed between the two hospitals of this study due to workflow differences, with cone-beam CT playing a dominant role. No significant differences in left and right eye Hp (3) values were observed between the hospitals. For both hospitals, the Hp (3) values were below the recommended limits, indicating that radiation monitoring may not be required for AFB procedures. This study provides insights into radiation exposure during AFB procedures, concerning radiation dosimetry, and safety for patients and physicians.

Funder

National Tsing Hua University

National Taiwan University Hospital Hsin-Chu Branch

Publisher

IOP Publishing

Subject

Public Health, Environmental and Occupational Health,Waste Management and Disposal,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3