Dose quantities for measurement and comparison of doses to individual patients in computed tomography (CT)

Author:

Martin Colin JORCID,Abuhaimed AbdullahORCID,Lee ChoonsikORCID

Abstract

Abstract The dose quantities displayed routinely on CT scanners, the volume averaged CT dose index (CTDIvol) and dose length product, provide measures of doses calculated for standard phantoms. The American Association of Medical Physics has published conversion factors for the adjustment of CTDIvol to take account of variations in patient size, the results being termed size-specific dose estimate (SSDE). However, CTDIvol and SSDE, while useful in comparing and optimising doses from a set procedure, do not provide risk-related information that takes account of the organs and tissues irradiated and associated cancer risks. A derivative of effective dose that takes account of differences in body and organ sizes and masses, referred to here as size-specific effective dose (SED), can provide such information. Data on organ doses from NCICT software that is based on Monte Carlo simulations of CT scans for 193 adult phantoms have been used to compute values of SED for CT examinations of the trunk and results compared with corresponding values of SSDE. Relationships within ±8% were observed between SED and SSDE for scans extending over similar regions for phantoms with a wide range of sizes. Coefficients have been derived from fits of the data to estimate SED values from SSDEs for different regions of the body for scans of standard lengths based on patient height. A method developed to take account of differences in scan length gave SED results within ±5% of values calculated using the NCI phantom library. This approach could potentially be used to estimate SED from SSDE values, allowing their display at the time a CT scan is performed.

Publisher

IOP Publishing

Subject

Public Health, Environmental and Occupational Health,Waste Management and Disposal,General Medicine

Reference36 articles.

1. The measurement, reporting, and management of radiation dose in CT,2008

2. Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations,2011

3. Use of water equivalent diameter for calculating patient size and size-specific dose estimates (SSDE) in CT,2014

4. Size specific dose estimate (SSDE) for head CT,2019

5. Estimation of size-specific dose estimates (SSDE) for paediatric and adults patients based on a single slice;Abuhaimed;Phys. Medica,2020

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3