Carotid Doppler ultrasound for non-invasive haemodynamic monitoring: a narrative review

Author:

Suriani IreneORCID,van Houte JorisORCID,de Boer Esmée CORCID,van Knippenberg LuukORCID,Manzari Sabina,Mischi MassimoORCID,Bouwman R ArthurORCID

Abstract

Abstract Objective. Accurate haemodynamic monitoring is the cornerstone in the management of critically ill patients. It guides the optimization of tissue and organ perfusion in order to prevent multiple organ failure. In the past decades, carotid Doppler ultrasound (CDU) has been explored as a non-invasive alternative for long-established invasive haemodynamic monitoring techniques. Considering the large heterogeneity in reported studies, we conducted a review of the literature to clarify the current status of CDU as a haemodynamic monitoring tool. Approach. In this article, firstly an overview is given of the equipment and workflow required to perform a CDU exam in clinical practice, the limitations and technical challenges potentially faced by the CDU sonographer, and the cerebrovascular mechanisms that may influence CDU measurement outcomes. The following chapter describes alternative techniques for non-invasive haemodynamic monitoring, detailing advantages and limitations compared to CDU. Next, a comprehensive review of the literature regarding the use of CDU for haemodynamic monitoring is presented. Furthermore, feasibility aspects, training requirements and technical developments of CDU are addressed. Main results. Based on the outcomes of these studies, we assess the applicability of CDU-derived parameters within three clinical domains (cardiac output, volume status, and fluid responsiveness), and amongst different patient groups. Finally, recommendations are provided to improve the quality and standardization of future research and clinical practice in this field. Significance. Although CDU is not yet interchangeable with invasive ‘gold standard’ cardiac output monitoring, the present work shows that certain CDU-derived parameters prove promising in the context of functional haemodynamic monitoring.

Funder

Nederlandse Organisatie voor Wetenschappelijk Onderzoek

Publisher

IOP Publishing

Subject

Physiology (medical),Biomedical Engineering,Physiology,Biophysics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3