Simulation study on high spatio-temporal resolution acousto-electrophysiological neuroimaging

Author:

Schoeters RubenORCID,Tarnaud ThomasORCID,Martens LucORCID,Tanghe EmmericORCID

Abstract

Abstract Objective. Acousto-electrophysiological neuroimaging (AENI) is a technique hypothesized to record electrophysiological activity of the brain with millimeter spatial and sub-millisecond temporal resolution. This improvement is obtained by tagging areas with focused ultrasound (fUS). Due to mechanical vibration with respect to the measuring electrodes, the electrical activity of the marked region will be modulated onto the ultrasonic frequency. The region’s electrical activity can subsequently be retrieved via demodulation of the measured signal. In this study, the feasibility of this hypothesized technique is tested. Approach. This is done by calculating the forward electroencephalography response under quasi-static assumptions. The head is simplified as a set of concentric spheres. Two sizes are evaluated representing human and mouse brains. Moreover, feasibility is assessed for wet and dry transcranial, and for cortically placed electrodes. The activity sources are modeled by dipoles, with their current intensity profile drawn from a power-law power spectral density. Results. It is shown that mechanical vibration modulates the endogenous activity onto the ultrasonic frequency. The signal strength depends non-linearly on the alignment between dipole orientation, vibration direction and recording point. The strongest signal is measured when these three dependencies are perfectly aligned. The signal strengths are in the pV-range for a dipole moment of 5 nAm and ultrasonic pressures within Food and Drug Administration (FDA)-limits. The endogenous activity can then be accurately reconstructed via demodulation. Two interference types are investigated: vibrational and static. Depending on the vibrational interference, it is shown that millimeter resolution signal detection is possible also for deep brain regions. Subsequently, successful demodulation depends on the static interference, that at MHz-range has to be sub-picovolt. Significance. Our results show that mechanical vibration is a possible underlying mechanism of acousto-electrophyisological neuroimaging. This paper is a first step towards improved understanding of the conditions under which AENI is feasible.

Funder

Fonds Wetenschappelijk Onderzoek

Publisher

IOP Publishing

Subject

Cellular and Molecular Neuroscience,Biomedical Engineering

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3