Towards single-trial classification of invasively recorded auditory evoked potentials in cochlear implant users

Author:

Bauernfeind GORCID,Teschner M J,Wriessnegger S CORCID,Büchner A,Lenarz T,Haumann SORCID

Abstract

Abstract Objective. One promising approach towards further improving cochlear implants (CI) is to use brain signals controlling the device in order to close the auditory loop. Initial electroencephalography (EEG) studies have already shown promising results. However, they are based on noninvasive measurements, whereas implanted electrodes are expected to be more convenient in terms of everyday-life usability. If additional measurement electrodes were implanted during CI surgery, then invasive recordings should be possible. Furthermore, implantation will provide better signal quality, higher robustness to artefacts, and thus enhanced classification accuracy. Approach. In an initial project, three additional epidural electrodes were temporarily implanted during the surgical procedure. After surgery, different auditory evoked potentials (AEPs) were recorded both invasively (epidural) and using surface electrodes, with invasively recorded signals demonstrated as being markedly superior. In this present analysis, cortical evoked response audiometry (CERA) signals recorded in seven patients were used for single-trial classification of sounds with different intensities. For classification purposes, we used shrinkage-regularized linear discriminant analysis (sLDA). Clinical speech perception scores were also investigated. Main results. Analysis of CERA data from different subjects showed single-trial classification accuracies of up to 99.2% for perceived vs. non-perceived sounds. Accuracies of up to 89.1% were achieved in classification of sounds perceived at different intensities. Highest classification accuracies were achieved by means of epidural recordings. Required loudness differences seemed to correspond to speech perception in noise. Significance. The proposed epidural recording approach showed good classification accuracy into sound perceived and not perceived when the best-performing electrodes were selected. Classifying different levels of sound stimulation accurately proved more challenging. At present, the methods explored in this study would not be sufficiently reliable to allow automated closed-loop control of CI parameters. However, our findings are an important initial contribution towards improving applicability of closed auditory loops and for next-generation automatic fitting approaches.

Funder

Deutsche Forschungsgemeinschaft

Publisher

IOP Publishing

Subject

Cellular and Molecular Neuroscience,Biomedical Engineering

Reference41 articles.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3