Author:
Arnold Christopher,Pobel Christoph,Osmanlic Fuad,Körner Carolin
Abstract
Purpose
The purpose of this study is the introduction and validation of a new technique for process monitoring during electron beam melting (EBM).
Design/methodology/approach
In this study, a backscatter electron detector inside the building chamber is used for image acquisition during EBM process. By systematic variation of process parameters, the ability of displaying different topographies, especially pores, is investigated. The results are evaluated in terms of porosity and compared with optical microscopy and X-ray computed tomography.
Findings
The method is capable of detecting major flaws (e.g. pores) and gives information about the quality of the resulting component.
Originality/value
Image acquisition by evaluating backscatter electrons during EBM process is a new approach in process monitoring which avoids disadvantages restricting previously investigated techniques.
Subject
Industrial and Manufacturing Engineering,Mechanical Engineering
Reference12 articles.
1. Defect generation and propagation mechanism during additive manufacturing by selective beam melting;Journal of Materials Processing Technology,2014
2. Thermographic in-situ process monitoring of the electron-beam melting technology used in additive manufacturing,2013
3. Review of in-situ process monitoring and in-situ metrology for metal additive manufacturing;Materials & Design,2016
4. Process defects and in situ monitoring methods in metal powder bed fusion: a review;Measurement Science and Technology,2017
5. Processing window and evaporation phenomena for Ti-6Al-4V produced by selective electron beam melting;Acta Materialia,2014
Cited by
51 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献