Manufacturability study in laser powder bed fusion of biomedical Ti alloys for orthopedic implants: an investigation of mechanical properties, process-induced porosity and surface roughness

Author:

Rehman Mudassar,Wang Yanen,Ishfaq Kashif,Yang Haiou,Mushtaq Ray Tahir,Kumar M. Saravana,Ahmed Ammar

Abstract

Purpose Since the biomedical implants with an improved compressive strength, near bone elastic modulus, controlled porosity, and sufficient surface roughness, can assist in long term implantation. Therefore, the fine process tuning plays its crucial role to develop optimal settings to achieve these desired properties. This paper aims to find applications for fine process tuning in laser powder bed fusion of biomedical Ti alloys for load-bearing implants. Design/methodology/approach In this work, the parametric porosity simulations were initially performed to simulate the process-induced porosity for selective laser-melted Ti6Al4V as per full factorial design. Continually, the experiments were performed to validate the simulation results and perform multiresponse optimization to fine-tune the processing parameters. Three levels of each control variable, namely, laser power – Pl (180, 190, 200) W, scanning speed – Vs (1500, 1600, 1700) mm/s and scan orientation – ϴ{1(0,0), 2(0,67°), 3(0,90°)} were used to investigate the processing performance. The measured properties from this study include compressive yield strength, elastic modulus, process-induced porosity and surface roughness. Finally, confirmatory experiments and comparisons with the already published works were also performed to validate the research results. Findings The results of porosity parametric simulation and experiments in selective laser melting of Ti6Al4V were found close to each other with overall porosity (less than 10%). The fine process tuning was resulted in optimal settings [Pl (200 W), Vs (1500 mm/s), ϴ (0,90°)], [Pl (200 W), Vs (1500 mm/s), ϴ (0,67°)], [Pl (200 W), Vs (1500 mm/s), ϴ (0,0)] and [Pl (200 W), Vs (1500 mm/s), ϴ (0,0)] with higher compressive strength (672.78 MPa), near cortical bone elastic modulus (12.932 GPa), process-induced porosity (0.751%) and minimum surface roughness (2.72 µm). The morphology of the selective laser melted (SLMed) surface indicated that the lack of fusion pores was prominent because of low laser energy density among the laser and powder bed. Confirmatory experimentation revealed that an overall percent improvement of around 15% was found between predicted and the experimental values. Originality/value Since no significant works are available on the collaborative optimization and fine process tuning in laser powder bed fusion of biomedical Ti alloys for different load bearing implants. Therefore, this work involves the comprehensive investigation and multi-objective optimization to determine optimal parametric settings for better mechanical and physical properties. Another novel aspect is the parametric porosity simulation using Ansys Additive to assist in process parameters and their levels selection. As a result, selective laser melted Ti alloys at optimal settings may help in examining the possibility for manufacturing metallic implants for load-bearing applications.

Publisher

Emerald

Subject

Industrial and Manufacturing Engineering,Mechanical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3