Author:
Greenspan H. P.,Carrier G. F.
Abstract
The uniform steady flow of an incompressible, viscous, electrically conducting fluid is distorted by the presence of a symmetrically oriented semi-infinite flat plate. The ambient magnetic field is coincident with the ambient velocity field. The description of the resulting fields depends on the physical co-ordinates measured in units of Reynolds number and on the two parameters ε = ωμν and β = μH2/ρv2. This description of the fields is approximated in three different ways and essentially covers the full range of ε and β. In particular, when β [Gt ] 1, no steady flow which is uniform at large distances from the plate exists.
Publisher
Cambridge University Press (CUP)
Subject
Mechanical Engineering,Mechanics of Materials,Condensed Matter Physics
Reference7 articles.
1. Pearson, C. E. 1957 On the finite strip problem.Quart. Appl. Math. 15,203.
2. Carrier, G. F. 1953 Boundary layer problems in applied mechanics. Advances in Applied Mechanics , vol. III.New York:Academic Press.
3. Foster, R. M. & Campbell, G. A. 1948 Fourier Integrals .New York:D. Van Nostrand Co.
4. Carrier, G. F. 1959 Technique for the solution of problems involving diffusion and convection. (To be published inQuart. Appl. Math.)
5. Lewis, F. A. & Carrier, G. F. 1949 Some remarks on the flat plate boundary layer.Quart. Appl. Math. 7,228.
Cited by
127 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献