The dosimetric impact of manual adjustments following automated registration in prostate image-guided radiotherapy

Author:

ElBeltagi Mohamed Nazmy,Harper Dean,Coleman Lisa

Abstract

AbstractAimAlthough manual adjustment of automatic cone beam computed tomography (CBCT) matching may improve the target coverage in certain points of interest, concerns exist that this may lead to dosimetric uncertainties which would negate the theoretical benefit of this approach. The objective of this study is to evaluate the dosimetric impact of manual adjustments made after automatic bony registration on CBCT in prostate patients.MethodsA total of 50 CBCT datasets of ten high-risk prostate cancer patients were randomly chosen. Each CBCT dataset was registered three times. Method (A): Automatic registration, Method (M1): Manual adjustment carried out by two experienced radiation therapists, Method (M2): Manual adjustment carried out by different radiation therapists with varying levels of experience. The clinical target volume (CTV), planning target volume (PTV), the bladder and the rectum were subsequently contoured on each CBCT dataset by a radiation oncologist blinded to the registration methods. The absolute difference of various dosimetric parameters were then analysed and compared with the original planning doses. A comparison of the three matching methods employed was also carried out.ResultsThere was a statistically significant difference in the magnitude of move taken in the inferior superior direction between M1 and M2 method. There were no significant differences observed in any of the dosimetric parameters examined in relation to the rectum, bladder or CTV. The only significant difference observed was the volume of PTV covered by the prescription isodose (95%) which was statistically significant lower in method A compared with both M1 and M2. There was no difference observed between M1 and M2 methods. The mean duration of the automated registration and subsequent analysis was 64 seconds compared with 91 seconds for automated registrations which included the additional manual adjustment.FindingsCBCT-based manual adjustments of automated bony-based registrations during the image-guided radiotherapy verification of prostate cancer patients can improve PTV coverage without impacting negatively on the doses received by the organs at risk. This strategy is associated with a small increase in overall treatment time.

Publisher

Cambridge University Press (CUP)

Subject

Oncology,Radiology Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3